05.01.2015 Views

Download - TDK-Lambda

Download - TDK-Lambda

Download - TDK-Lambda

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

NEW<br />

Specifications Genesys GEN 750 W Power Sink (Option)<br />

Specifications Power Sink (750 W)<br />

GEN12.5-60 PSINK<br />

Sink power rating<br />

Max. peak power (thermal limited) Tamb = 25 °C [W] 200<br />

Max. peak power (thermal limited) Tamb = 50 °C [W] 100<br />

Max. sink peak power duration [s] 30<br />

Recovery time for max. peak power [s] 1200<br />

Max. continues power, Tamb = 25 °C [W] 45<br />

Max. continues power, Tamb = 50 °C [W] 30<br />

Power derate above 25 °C [%/ °C] 1.33<br />

Duty cycle for use at peak power<br />

PSINK = 70 W, Tamb = 25 °C [s] ton ≤ 10 s, toff ≥ 10 s<br />

PSINK = 70 W, Tamb = 25 °C [s] ton ≤ 20 s, toff ≥ 21 s<br />

PSINK = 70 W, Tamb = 25 °C [s] ton ≤ 30 s, toff ≥ 36 s<br />

PSINK = 105 W, Tamb = 25 °C [s] ton ≤ 10 s, toff ≥ 22 s<br />

PSINK = 105 W, Tamb = 25 °C [s] ton ≤ 20 s, toff ≥ 50 s<br />

PSINK = 105 W, Tamb = 25 °C [s] ton ≤ 30 s, toff ≥ 90 s<br />

PSINK = 140 W, Tamb = 25 °C [s] ton ≤ 10 s, toff ≥ 40 s<br />

PSINK = 140 W, Tamb = 25 °C [s] ton ≤ 20 s, toff ≥ 90 s<br />

PSINK = 140 W, Tamb = 25 °C [s] ton ≤ 30 s, toff ≥ 170 s<br />

Power derate above 25 °C [%/ °C] 2<br />

Protection<br />

Electronic power limit, over current<br />

Max. sink current [A] 65<br />

Sink over voltage protection typical trip point<br />

(In case of higher sink current than the maximum current)<br />

[V] 15.5 – 19.5<br />

Thermal overload protection<br />

In case of power sink thermal<br />

Recovery time / deviation<br />

Load current switches from positive to negative<br />

GEN12.5-60 PSINK<br />

Vout = 6 V, Iout = +20 A → –10 A<br />

Deviation [V] 0.4<br />

Percentage [%] 6.67<br />

Recovery to 0.5 % or 100 mV whichever is greater [ms] 5.5<br />

Vout = 12.5 V, Iout = +15 A → –5 A<br />

Deviation [V] 0.35<br />

Percentage [%] 2.8<br />

Recovery to 0.5 % or 100 mV whichever is greater [ms] 2.5<br />

Vout = 20 V, Iout = +12 A → –4 A<br />

Deviation<br />

[V]<br />

Percentage [%]<br />

Recovery to 0.5 % or 100 mV whichever is greater<br />

[ms]<br />

Vout = 30 V, Iout = +10 A → –2 A<br />

Deviation<br />

[V]<br />

Percentage [%]<br />

Recovery to 0.5 % or 100 mV whichever is greater<br />

[ms]<br />

40