Specifications Genesys GEN 5 kW<br />
Model GEN 8-600 10-500 16-310 20-250<br />
Rated output voltage (*1) [V] 8 10 16 20<br />
Rated output current (*2) [A] 600 500 310 250<br />
Rated output power [W] 4800 5000 4960 5000<br />
Constant Current Mode<br />
Max. line regulation (0.05 % of rated lo) (*3) [mA] 300 250 155 125<br />
Max. load regulation (0.1 % of rated lo) (*8) [mA] 600 500 310 250<br />
Ripple RMS 5 Hz~1 MHz (*9) [mA] 1950 1800 1400 1000<br />
Load regulation thermal drift<br />
Less than 0.1 % of rated output current over<br />
Temperature coefficient [ppm/°C] 100 ppm/°C from rated output current, following<br />
Temperature stability<br />
0.05 % of rated Iout over 8 hrs interval following<br />
Warm-up drift<br />
8~16 V model: Less than ±0.5 % rated output current<br />
Constant Voltage Mode<br />
Max. line regulation (0.01 % of rated Vo) (*3) [mV] 0.8 1.0 1.6 2<br />
Max. load regulation (0.015 % of rated Vo + 5 mV) (*4) [mV] 6.2 6.5 7.4 8<br />
Ripple and noise p-p 20 MHz (*5) [mV] 75 75 75 75<br />
Ripple RMS 5 Hz~1 MHz [mV] 10 10 10 10<br />
Remote sense compensation/wire [V] 2 2 2 2<br />
Temperature coefficient [ppm/°C] 100 ppm/°C of rated output voltage, following<br />
Temperature stability<br />
0.05 % of rated Vout over 8 hrs interval following<br />
Warm-up drift<br />
Less than 0.05 % of rated output voltage + 2 mV<br />
Up-prog. response time, 0~Vo Rated (*6) [ms] 30<br />
Down-prog. response time Full-load (*6) [ms] 15 50<br />
No-load (*7) [ms] 400 500 600 700<br />
Transient response time [ms] Time for output voltage to recover within 0.5 % of its<br />
Less than 1 ms for models up to and including 100 V.<br />
*1: Minimum voltage is guaranteed to maximum 0.2 % of rated output voltage.<br />
*2: Minimum current is guaranteed to maximum 0.4 % of rated output current.<br />
*3: 3-Phase 208 V models: 170~265 V AC, constant load.<br />
3-Phase 400 V models: 342~460 V AC, constant load.<br />
*4: From No-Load to Full-Load, constant input voltage. Maximum drop in Remote<br />
Sense.<br />
*5: For 8 V~300 V models: Measured with JEITA RC-9131A (1:1) probe.<br />
For 600 V model: Measured with 10:1 probe.<br />
*6: From 10 % to 90 % or 90 % to 10 % of Rated Output Voltage, with rated,<br />
resistive load.<br />
*7: From 90 % to 10 % of Rated Output Voltage.<br />