Model Z 10-75 20-40 36-24 60-14 100-8<br />

Programming and readback (RS232/485, USB, Optional: IEEE; LAN)<br />

Vout programming accuracy<br />

Iout programming accuracy (*13)<br />

Vout programming resolution<br />

Iout programming resolution<br />

Vout readback accuracy<br />

Iout readback accuracy (*13)<br />

Vout readback resolution<br />

Iout readback resolution<br />

0.05 % of rated output voltage<br />

0.1 % of rated output current<br />

0.012 % of full scale<br />

0.012 % of full scale<br />

0.05 % of rated output voltage<br />

0.1 % of rated output current<br />

0.012 % of full scale<br />

0.012 % of full scale<br />

Input Characteristics<br />

Input voltage/freq. (*3)<br />

85~265 V AC continuous, 47~63 Hz, Single-Phase<br />

Maximum Input current 100/200 V AC (*18) 9.25/4.50 9.65/4.70 10.30/5.02 10.00/4.90 9.5/4.65<br />

Power Factor (Typ)<br />

0.99 at 100/200 V AC, 100 % load<br />

Efficiency (Typ) 100/200 V AC (*4) (*18) [%] 80/82 82/84 84/85 83/85 84/86<br />

Inrush current (*5)<br />

Less than 25 A<br />

Environmental Conditions<br />

Operating temperature<br />

0~50 °C, 100 % load.<br />

Storage temperature -20~85 °C<br />

Operating humidity [%] 20~90 % RH (no condensation).<br />

Storage humidity [%] 10~95 % RH (no condensation).<br />

Altitude Maximum 3000 m. Derate ambient temp above 2000 m.<br />

Operating: Maximum ambient temperature, from 2000 m up to 3000 m<br />

Ambient temperature 40 °C.<br />

Safety/EMC<br />

Applicable standards: Safety UL61010-1, EN61010-1, IEC61010-1. Design to meet UL60950-1, EN60950-1<br />

EMC<br />

IEC61326-1 (Built to meet EN55022/EN55024)<br />

Withstand voltage Safety USB, LAN/IEEE/ISOLATED ANALOG: 4242 V DC / 1 min; Input-Ground:<br />

2828 V DC / 1 min.<br />

Output & J1, J2, J3, J4, USB, LAN/IEEE/ISOLATED ANALOG-Ground:<br />

1000 V DC / 1 min.<br />

60 V, 100 V models: Input-Output & J1, J2: 4242 V DC / 1 min; Input-J3, J4,<br />

USB, LAN/IEEE/ISOLATED Analog: 4242 V DC / 1 min; Input-Ground: 2828<br />

V DC / 1 min.<br />

Output & J1, J2 - J3, J4, USB, LAN/IEEE/ISOLATED ANALOG:1910 V DC /<br />

1 min; Output & J1, J2-Ground: 1380 V DC / 1 min.<br />

J3, J4, USB/LAN/IEEE/ISOLATED ANALOG - Ground: 1000 V DC / 1 min;<br />

Insulation resistance<br />

More than 100 MΩ at 25 °C, 70 % RH.<br />

Conducted emission<br />

EN55022B, FCC part 15-B, VCCI-B<br />

Radiated emission<br />

EN55022B, FCC part 15-B, VCCI-B<br />

Mechanical<br />

Cooling<br />

Forced air cooling by internal fan.<br />

Weight Standard [kg] Less than 2.5 kg<br />

Wide Body<br />

Less than 3.0 kg. Wide body with Isolated analog or Binding post or IEEE.<br />

Dimensions<br />

(W x H x D)<br />

Standard [mm] H: 83, W: 70, D: 350 (excluding bus bars, handles…).<br />

(Refer to Outline drawing).<br />

Wide Body<br />

H: 83, W: 105, D: 350 (excluding bus bars, handles…).<br />

(Refer to Outline drawing).<br />

Shock<br />

According to: IEC60068-2-64<br />

Less than 20 G, half sine, 11 ms. Unit is unpacked. According to:<br />

IEC600068-2-27<br />

*12: For 10 V model the ripple is measured at 2 V to rated output voltage and rated out<br />

put current. For other models, the ripple is measured at 10~100 % of rated output<br />

voltage and rated output current.<br />

*13: The Constant Current programming, readback and monitoring accuracy do not<br />

include the warm-up and Load regulation thermal drift.<br />

*14: Measured with JEITA RC-9131A (1:1) probe.<br />

20<br />

*15: For cases where the time interval between each down programming is longer than<br />

Td (time delay).<br />

*16: For cases where the time interval between each down programming is shorter than<br />

Td (time delay).<br />

*17: Td typical (±20 %) Minimum time between consecutive down programming cycles.<br />

*18: PS with isolated analog option decreases efficiency by 0.5 % and increases input<br />

current by 0.5 %