Outline drawings Genesys GEN 2400 W Units<br />
43.6 ±0.3 mm<br />
482.8 ±1.0 mm<br />
422.8 ±1.0 mm<br />
1 2 3<br />
Bus-Bar Detail<br />
8 V to 100 V Models<br />
3.0 mm<br />
39.5 ±0.5 mm<br />
22.0 mm<br />
8.5 mm<br />
30.0 mm<br />
4 4 4<br />
603.0 ±1.0 mm<br />
A<br />
A<br />
A<br />
57.8 ±0.5 92.0 ±0.5 mm 92.0 ±0.5 mm<br />
21.0<br />
440.8 ±1.0 mm<br />
6<br />
5<br />
505.8 ±1.0 mm<br />
1 Mating plug supplied with power supply.<br />
2 DC output:<br />
Bus-bars for 8 V to 100 V models, wire<br />
clamp terminal for 150 V to 600 V models.<br />
(shown)<br />
3 Auxilary output. Mating plug P/N: IMC<br />
1.5/7-ST-3.8.1 Phoenix.<br />
4 Chassis slides: GENERAL DEVICES P/N:<br />
CC3001-00-S160 or equivalent mounting<br />
holes #10-32 marked “A”.<br />
5 AC cable strain relief supplied with power<br />
supply.<br />
6 Bus-bars enclosure for 60 V ~ 600 V.<br />