Recovery time / deviation<br />
Load current switches from positive to negative (750 W)<br />
GEN12.5-60 PSINK<br />
Vout = 40 V, Iout = +8 A → –1 A<br />
Deviation<br />
[V]<br />
Percentage [%]<br />
Recovery to 0.5 % or 100 mV whichever is greater<br />
[ms]<br />
Vout = 60 V, Iout = +5 A → –1 A<br />
Deviation<br />
[V]<br />
Percentage [%]<br />
Recovery to 0.5 % or 100 mV whichever is greater<br />
[ms]<br />
Programming down speed<br />
12.5 → 0 V<br />
Fall time (90 % – 10 %) (1*) [ms] < 3<br />
Note 1: In case of Analog programming Fall time slew rate is 200 µs/1 V.<br />
Note 2: Values are typical at 25 °C<br />
NEW<br />
Specifications Genesys GEN 1500 W Power Sink (Option)<br />
Specifications Power Sink (1500 W)<br />
GEN12.5-120 PSINK<br />
Sink power rating<br />
Max. peak power (thermal limited) Tamb = 25 °C [W] 200<br />
Max. peak power (thermal limited) Tamb = 50 °C [W] 100<br />
Max. sink peak power duration [s] 30<br />
Recovery time for max. peak power [s] 900<br />
Max. continues power, Tamb = 25 °C [W] 55<br />
Max. continues power, Tamb = 50 °C [W] 35<br />
Power derate above 25 °C [%/ °C] 1.5<br />
Duty cycle for use at peak power<br />
PSINK = 80 W, Tamb = 25 °C [s] ton ≤ 10 s, toff ≥ 10 s<br />
PSINK = 80 W, Tamb = 25 °C [s] ton ≤ 20 s, toff ≥ 21 s<br />
PSINK = 80 W, Tamb = 25 °C [s] ton ≤ 30 s, toff ≥ 36 s<br />
PSINK = 120 W, Tamb = 25 °C [s] ton ≤ 10 s, toff ≥ 22 s<br />
PSINK = 120 W, Tamb = 25 °C [s] ton ≤ 20 s, toff ≥ 50 s<br />
PSINK = 120 W, Tamb = 25 °C [s] ton ≤ 30 s, toff ≥ 90 s<br />
PSINK = 160 W, Tamb = 25 °C [s] ton ≤ 10 s, toff ≥ 40 s<br />
PSINK = 160 W, Tamb = 25 °C [s] ton ≤ 20 s, toff ≥ 90 s<br />
PSINK = 160 W, Tamb = 25 °C [s] ton ≤ 30 s, toff ≥ 170 s<br />
Power derate above 25 °C [%/ °C] 2<br />
Protection<br />
Electronic power limit, over current<br />
Max. sink current [A] 65<br />
Sink over voltage protection typical trip point<br />
(In case of higher sink current than the maximum current)<br />
[V] 15.5 – 19.5<br />
Thermal overload protection<br />
In case of power sink thermal<br />
Recovery time / deviation<br />
Load current switches from positive to negative<br />
GEN12.5-120 PSINK<br />
Vout = 6 V, Iout = +40 A → – 15 A<br />
Deviation [V] 0.5<br />
Percentage [%] 8.33<br />
Recovery to 0.5 % or 100 mV whichever is greater [ms] 5.5<br />
42