EMC<br />

208 V input models CE Mark<br />

ESD<br />

EN61000-4-2 (IEC 801-2) air-disch. ±8 kV, contact disch. ±4 kV<br />

Fast transients EN61000-4-4 (IEC 1000-4-3)<br />

Surge immunity EN61000-4-5 (IEC 1000-4-5)<br />

Conducted immunity EN61000-4-6 (IEC 1000-4-6)<br />

Radiated immunity EN61000-4-3 (IEC 1000-4-3)<br />

Power frequency magnetic field<br />

EN61000-4-8<br />

Conducted emission<br />

EN55011A, FCC part 15J-A<br />

Radiated emission<br />

EN55011A, FCC part 15J-A<br />

400 V input models CE Mark<br />

ESD<br />

EN61000-4-2 (IEC 801-2) Air-disch. ±8 kV, contact disch. ±4 kV<br />

Fast transients EN61000-4-4 (IEC 1000-4-3)<br />

Surge immunity EN61000-4-5 (IEC 1000-4-5)<br />

Conducted immunity EN61000-4-6 (IEC 1000-4-6)<br />

Radiated immunity EN61000-4-3 (IEC 1000-4-3)<br />

Power frequency magnetic field<br />

EN61000-4-8<br />

Voltage dips, short interruptions and voltage IEC 61000-4-11<br />

variations immunity tests (400 V AC only)<br />

Conducted emission<br />

Radiated emission<br />

EN55011A, FCC part 15J-A<br />

EN55011A, FCC part 15J-A<br />

Safety<br />

Applicable standards UL 60950-1:2007 (Ed.2), IEC 60950-1:2005 (ED. 2), EN60950-1:2006 (Ed. 2)<br />

Vout ≤ 40 V: Output is SELV, IEEE/Isolated Analog/LAN/USB are SELV<br />

40< Vout ≤ 400 V: Output hazardous; IEEE/Isolated Analog/LAN/USB are SELV<br />

400< Vout ≤ 600 V: Output hazardous; IEEE/Isolated Analog/LAN/USB are SELV,<br />

CE Mark 208 & 400 V AC Inputs only (CB Scheme)<br />

Insulation resistance<br />

Withstand Voltage<br />

Mechanical Construction<br />

Cooling<br />

Dimensions (WxHxD)<br />

Weight<br />

Types of connectors<br />

Mounting method<br />

Output ground connection<br />

Reliability specs<br />

Warranty<br />

100 MΩ at 500 V DC<br />

Vout ≤ 60 V models: Input-Ground: 2818 V DC 1 min., Input-Outputs (SELV):<br />

4242 V DC 1 min. Output-Ground: 1000 V DC 1 min.<br />

60< Vout ≤ 300 V models: Input-Ground: 2828 V DC 1 min., Input-Haz. Output:<br />

3535 V DC 1 min. Input-SELV: 2828 V DC 1 min.<br />

Hazardous Output-SELV: 2121 V DC 1 min. Hazardous Output-Ground: 2121 V<br />

DC 1 min.<br />