Specifications Genesys GEN / GENH 750 / 1500 W<br />

Interface RS-232 & RS-485 or Optional GPIB / LAN Interface<br />

Model 6 8 12.5 20<br />

Remote Current Programming (16 bit) (750 W)<br />

Resolution (0.012 % of lo Rated) [mA] 12 10.8 7.2 4.56<br />

Accuracy (0.1 % lo Rated + 0.1 % of lo Actual Output) [mA] 200 180 120 76<br />

Readback Current (750 W)<br />

Resolution (0.012 % of lo Rated) [mA] 12 10.8 7.2 4.56<br />

Accuracy (0.3 % lo Rated + 0.1 % of lo Actual Output) [mA] 400 360 240 152<br />

Remote Current Programming (16 bit) (1500 W)<br />

Resolution (0.012 % of lo Rated) [mA] 24 21.6 14.4 9.12<br />

Accuracy (0.1 % lo Rated + 0.1 % of lo Actual Output) [mA] 400 360 240 152<br />

Readback Current (1500 W)<br />

Resolution (0.012 % of lo Rated) [mA] 24 21.6 14.4 9.12<br />

Accuracy (0.3 % lo Rated + 0.1 % of lo Actual Output) [mA] 800 720 480 304<br />

Remote Voltage Programming (16 bit) (750/1500 W)<br />

Resolution (0.012 % of Vo Rated) [mV] 0.72 0.96 1.50 2.40<br />

Accuracy (0.05 % Vo Rated + 0.05 % of Vo Actual Output) [mV] 6.0 8.0 12.5 20<br />

Readback Voltage (750/1500 W)<br />

Resolution (0.012 % of Vo Rated) [mV] 0.72 0.96 1.50 2.40<br />

Accuracy (0.1 % Vo Rated + 0.1 % of Vo Actual Output) [mV] 12 16 25 40<br />

OVP/UVL Programming (750 W/1500 W)<br />

Resolution (0.1 % of Vo Rated) [mV] 6 8 12 20<br />

Accuracy (1 % of Vo Rated) [mV] 60 80 125 200<br />

Analog Programming and Monitoring (750 W/1500 W)<br />

Vout Voltage Programming<br />

Iout Voltage Programming<br />

Vout Resistor Programming<br />

Iout Resistor Programming<br />

On/Off control (rear panel)<br />

Output current monitor<br />

Output voltage monitor<br />

Power supply OK signal<br />

CV/CC indicator<br />

Enable/Disable<br />

Local/Remote analog control<br />

Local/Remote analog control indicator<br />

0~100 %, 0~5 V or 0~10 V, user-selectable.<br />

Accuracy and linearity: ± 0.5 % of rated Vout.<br />

0~100 %, 0~5 V or 0~10 V, user-selectable.<br />

Accuracy and linearity: ± 1 % of rated lout.<br />

0~100 %, 0~5/10 kΩ full scale, user-selectable.<br />

Accuracy and linearity: ± 1 % of rated Vout.<br />

0~100 %, 0~5/10 kΩ full scale, user-selectable.<br />

Accuracy and linearity: ± 1.5 % of rated lout.<br />

By electrical. Voltage: 0~0.6 V/2~15 V, or dry contact,<br />

user-selectable logic<br />

0~5 V or 0~10 V, accuracy: 1 %, user-selectable<br />

0~5 V or 0~10 V, accuracy: 1 %, user-selectable<br />

TTL high (4~5 V) -OK, 0 V-Fail 500 series resistance<br />

CV: TTL high (4~5 V), CC: TTL low (0~0.6 V),<br />

maximum Voltage: 30 V, sink current: 10 mA<br />

Dry contact. Open: off, Short: on. Max. voltage at<br />

Enable/Disable in: 6 V<br />

By electrical signal (TTL) or Open/Short: 0~0.6 V or short:<br />

Remote, 4~5 V or open: Local<br />

Open collector, Local: Open, Remote: On. Maximum voltage:<br />

30 V, maximum sink current: 5 mA<br />