05.01.2015 Views

Download - TDK-Lambda

Download - TDK-Lambda

Download - TDK-Lambda

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Specifications Genesys GEN / GENH 750 / 1500 W<br />

Power Supply Configuration<br />

Parallel operation<br />

Up to 4 units in master/slave mode with single wire current balance connection<br />

Series operation<br />

Up to 2 units with external diodes. 600 V max. to chassis ground<br />

Environmental Conditions<br />

Operating temperature<br />

0~50 °C, 100 % load<br />

Storage temperature –20~70 °C<br />

Operating humidity<br />

30~90 % RH (non-condensing)<br />

Storage humidity<br />

10~95 % RH (non-condensing)<br />

Vibration<br />

MIL-810E, method 514.4, test cond. I-3.3.1<br />

The EUT is fixed to the vibrating surface<br />

Shock<br />

Altitude<br />

EMC<br />

Applicable Standards:<br />

ESD<br />

Fast transients<br />

Surge immunity<br />

Conducted immunity<br />

Radiated immunity<br />

Conducted emission<br />

Radiated emission<br />

Voltage dips<br />

Conducted emission<br />

Radiated emission<br />

Less than 20 g, half sine, 11 ms unit is unpacked<br />

Operating: 10,000 ft (3,000 m), Derate output current by 2 %/100 m<br />

above 2,000 m, Non-operating: 40,000 ft (12,000 m)<br />

IEC1000-4-2. Air-disch. –8 kV, contact disch. –4 kV<br />

IEC1000-4-4. 2 kV<br />

IEC1000-4-5. 1 kV line to line, 2 kV line to ground<br />

IEC1000-4-6, 3 V<br />

IEC1000-4-3, 3 V/m<br />

EN55022B, FCC part 15J-B,VCCI-B<br />

EN55022A, FCC part 15-A,VCCI-A<br />

EN61000-4-11<br />

EN55022B, FCC part 15-B, VCCI-B<br />

EN55022A, FCC part 15-A, VCCI-A<br />

Safety<br />

Applicable standards: CE Mark, UL60950-1, EN60950-1: 2006 (Edition 2)<br />

Vout ≤40 V: Output is SELV, IEEE/Isolated analog are SELV<br />

40

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!