Specifications Genesys GEN 3.3 kW<br />
Model GEN 8-400 10-330 15-220<br />
Rated output voltage (*1) [V] 8 10 15<br />
Rated output current (*2) [A] 400 330 220<br />
Rated output power [W] 3200 3300 3300<br />
Constant Current Mode<br />
Max. line regulation (0.01 % of rated lo + 2 mA) (*3) [mA] 42 35 24<br />
Max. load regulation (0.02 % of rated lo + 5 mA) (*8) [mA] 85 71 49<br />
Ripple RMS 5 Hz~1 MHz (*9) [mA] 1300 1200 880<br />
Load regulation thermal drift<br />
Less than 0.1 % of rated output current<br />
Temperature coefficient [ppm/°C] 100 ppm/°C from rated output current,<br />
Temperature stability<br />
0.05 % of rated Iout over 8 hrs interval<br />
Warm-up drift<br />
8~20 V model: Less than ±0.5 % rated<br />
30~600 V model: Less than ±0.25 % of<br />
Constant Voltage Mode<br />
Max. line regulation (0.01 % of rated Vo + 2 mV) (*3) [mV] 2.8 3 3.5<br />
Max. load regulation (0.015 % of rated Vo + 5 mV) (*4) [mV] 6.2 6.5 7.25<br />
Ripple and noise p-p 20 MHz (*5) [mV] 60 60 60<br />
Ripple RMS 5 Hz~1 MHz [mV] 8 8 8<br />
Remote sense compensation/wire [V] 2 2 2<br />
Temperature coefficient [ppm/°C] 100 ppm/°C of rated output voltage,<br />
Temperature stability<br />
0.05 % of rated Vout over 8 hrs interval<br />
Warm-up drift<br />
Less than 0.05 % of rated output voltage<br />
Up-prog. response time, 0~Vo Rated (*6)<br />
[ms]<br />
Down-prog. response time Full-load (*6) [ms] 20 100<br />
No-load (*7) [ms] 500 600 700<br />
Transient response time [ms] Time for output voltage to recover within<br />
Output set-point: 10 – 100 %, local sense.<br />
Protective Functions<br />
OCP<br />
0~105 % Constant Current<br />
OCP Fold-back<br />
Output shut-down when power supply<br />
OVP type<br />
Inverter shut-down, manual reset by AC<br />
OVP trip point [V] 0.5~10 0.5~12 1~18<br />
Output under voltage limit<br />
Preset by front panel or communication<br />
Over Temperature Protection<br />
User-selectable, latched or non-latched<br />
*1: Minimum voltage is guaranteed to maximum 0.2 % of rated output voltage.<br />
*2: Minimum current is guaranteed to maximum 0.4 % of rated output current.<br />
*3: Single-Phase and 3-Phase 208 V models: 170~265 V AC, constant load.<br />
3-Phase 400 V models: 342~460 V AC, constant load.<br />
*4: From No-Load to Full-Load, constant input voltage. Maximum drop in Remote<br />
Sense.<br />
*5: For 8 V~300 V models: Measured with JEITA RC-9131A (1:1) probe.<br />
For 600 V model: Measured with 10:1 probe.<br />
*6: From 10 % to 90 % or 90 % to 10 % of Rated Output Voltage, with rated,<br />
resistive load.<br />
*7: From 90 % to 10 % of Rated Output Voltage.<br />
60