17.01.2015 Views

S T E P 1 - AO Smith Water Heaters

S T E P 1 - AO Smith Water Heaters

S T E P 1 - AO Smith Water Heaters

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LEGEND HEATERS<br />

SERVICE WORKBOOK<br />

SUPPLY VOLTAGE POLARITY CHECK<br />

LEGEND HEATERS<br />

SERVICE WORKBOOK<br />

LEGEND 2000 IRI CONNECTION DIAGRAM<br />

S<br />

T<br />

E<br />

P<br />

Supply voltage Polarity Check<br />

1 Using a multimeter, check supply black to ground, white to ground and<br />

green to ground voltage (in the junction box on the back of the<br />

Legend).<br />

RESULTS<br />

If the meter:<br />

does not read 120 VAC<br />

does read 120 VAC<br />

does not read “0” white to ground<br />

does read “0” white to ground<br />

then<br />

check supply voltage<br />

go to Step 2.<br />

check supply wiring<br />

go to Step 2.<br />

A.O. <strong>Smith</strong> <strong>Water</strong> Products Co.<br />

Irving, Texas © 1997<br />

20<br />

Service Workbook<br />

Training Department<br />

A.O. <strong>Smith</strong> <strong>Water</strong> Products Co.<br />

Irving, Texas © 1997<br />

61<br />

Service Workbook<br />

Training Department