LEGEND HEATERS<br />

SERVICE WORKBOOK<br />

SYSTEM (TANK TEMPERATURE) CONTROL TEST<br />

LEGEND HEATERS<br />

SERVICE WORKBOOK<br />

CONNECTION WIRING DIAGRAM FOR LW/LB-1000<br />

S<br />

T<br />

E<br />

P<br />

System (Tank Temperature) Control Test<br />

5 • Adjust control to call for heat.<br />

• Test for 24 VAC between each terminal of the system control and<br />

ground.<br />

RESULTS<br />

If the meter:<br />

then<br />

does not read 24 VAC to either terminal<br />

check wiring from the<br />

transformer.<br />

does not read 24 VAC on both terminals to ground replace control.<br />

reads 24 VAC on both terminals go to Step 6.<br />

A.O. <strong>Smith</strong> <strong>Water</strong> Products Co.<br />

Irving, Texas © 1997<br />

24<br />

Service Workbook<br />

Training Department<br />

A.O. <strong>Smith</strong> <strong>Water</strong> Products Co.<br />

Irving, Texas © 1997<br />

57<br />

Service Workbook<br />

Training Department