17.01.2015 Views

S T E P 1 - AO Smith Water Heaters

S T E P 1 - AO Smith Water Heaters

S T E P 1 - AO Smith Water Heaters

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

LEGEND HEATERS<br />

SERVICE WORKBOOK<br />

HSI CONTROL TERMINAL 9 TEST<br />

LEGEND HEATERS<br />

SERVICE WORKBOOK<br />

TABLE FOR STEP 29<br />

S<br />

T<br />

E<br />

P<br />

HSI Control Terminal 9 Test<br />

7 Test for 24 VAC between Ram HSI control terminal 9 and ground<br />

(terminal 6).<br />

Gas Valve Coil – OHMS Resistance Table<br />

LEGEND<br />

MODEL<br />

GAS<br />

TYPE<br />

#1 GAS VALVE<br />

MODEL<br />

LW/B-500<br />

LW/B-750<br />

NG<br />

and<br />

LPG<br />

Robertshaw 7000-<br />

DERHC-STA<br />

#1 GAS<br />

VALVE<br />

COIL OHMS*<br />

#2 GAS VALVE<br />

MODEL<br />

#2 G.V.<br />

COIL<br />

OHMS<br />

69 (TH-TR) __ 14 (Safety<br />

Gas Value)<br />

NG WR-2509-258 64 HNWL-V8843N1006 64<br />

LPG HNWL-V88A1626 64 HNWL-V88A1626 64<br />

LW/B-1000 NG ITT-K3AF671S 5000 HNWL-V8843N1022 64<br />

LW/B-1000 LPG HNWL-V88A1626 64 HNWL-V88A1626 64<br />

*Volts divided by AMPS = OHMS Resistance<br />

Legend Gas Valve Table<br />

Legend Model Type Gas Type Valve<br />

500 for USA and<br />

Canada<br />

750 USA<br />

USA & Canada<br />

Canada<br />

1000 USA and<br />

Canada<br />

Nat/Propane<br />

Natural<br />

Propane<br />

Natural<br />

Natural<br />

Propane<br />

LW Circulator Information<br />

Heater Model<br />

Dual Solenoid<br />

Diaphragm<br />

Solenoid<br />

Diaphragm<br />

Diaphragm<br />

Solenoid<br />

Diaphragm<br />

Solenoid<br />

MISCELLANEOUS INFORMATION ON LEGEND 2000<br />

<strong>Water</strong> GPM @<br />

20°TR<br />

Pressure Drop thru<br />

Heater<br />

Circulator<br />

HP<br />

Circulator<br />

Motor<br />

LW-500 44 12.5 ft. hd. 1 B&G 3531<br />

LW-750 66 17.76 ft. hd. 1 B&G 3531<br />

LW-1000 88 8.8 ft. hd. 1 TACO 1935<br />

AMP DRAW TABLE<br />

RESULTS<br />

If the meter:<br />

then<br />

does not read 24 VAC<br />

check wiring to operating<br />

control.<br />

does read 24 VAC go to Step 8.<br />

Heater Model Blower Amp Pump Amp Ignition System<br />

LW-500 120V; 3.5A 120V; 10.4FLA 120V; 5A Max<br />

LW-750 120V; 3.5A 120V; 14.0FLA 120V; 5A Max<br />

LW-1000 120V; 3.5A 120V; 15.4FLA 120V; 5A Max<br />

A.O. <strong>Smith</strong> <strong>Water</strong> Products Co.<br />

Irving, Texas © 1997<br />

26<br />

Service Workbook<br />

Training Department<br />

A.O. <strong>Smith</strong> <strong>Water</strong> Products Co.<br />

Irving, Texas © 1997<br />

55<br />

Service Workbook<br />

Training Department