HIGH LIMIT SWITCH TEST<br />

2R (120V SPDT) RELAY TERM 4 CHECK<br />

S<br />

T<br />

E<br />

P<br />

17<br />

High Limit Switch Test<br />

Control should be set at least 30° higher than the tank temperature<br />

control setting.<br />

Test for 24 VAC from each high limit terminal to ground.<br />

Ignition Proving Period<br />

RESULTS<br />

If the meter: and you are then<br />

does not read 24 VAC either<br />

check wire<br />

terminal to ground<br />

connection to yellow<br />

does read 24 VAC to only one<br />

terminal<br />

does read 24 VAC from each<br />

terminal to ground<br />

certain that the control is<br />

calling for heat and the<br />

reset button has been<br />

pushed<br />

flow switch terminal.<br />

replace control.<br />

go to step 18.<br />

S<br />

T<br />

E<br />

P<br />

24b<br />

LW/LB<br />

500 &<br />

750<br />

RESULTS<br />

2R (SPDT) Relay Term 4 Check<br />

Test for 120 VAC 2R relay terminal 4 to ground.<br />

If the meter:<br />

then<br />

does not read 120 VAC,<br />

replace 2R relay.<br />

does read 120 VAC, go to Step 24c.<br />

A.O. <strong>Smith</strong> <strong>Water</strong> Products Co.<br />

Irving, Texas © 1997<br />

36<br />

Service Workbook<br />

Training Department<br />

A.O. <strong>Smith</strong> <strong>Water</strong> Products Co.<br />

Irving, Texas © 1997<br />

45<br />

Service Workbook<br />

Training Department