LEGEND HEATERS<br />

SERVICE WORKBOOK<br />

LOW GAS PRESSURE SWITCH TEST<br />

LEGEND HEATERS<br />

SERVICE WORKBOOK<br />

CHECK OF IGNITOR<br />

S<br />

T<br />

E<br />

P<br />

RESULTS<br />

19<br />

Low Gas Pressure Switch Test<br />

This switch closes at 5.5” w.c. positive gas pressure on Natural gas,<br />

10.5” w.c. on Propane gas.<br />

Test for 24 VAC from each terminal to ground<br />

If the meter: and then<br />

does not read 24 VAC from either<br />

terminal to ground<br />

check wire connections<br />

between low gas pressure<br />

switch and blower prover<br />

reads 24 VAC from only one terminal<br />

and ground<br />

does read 24 VAC from each terminal<br />

to ground<br />

you have<br />

checked for<br />

proper gas<br />

pressure<br />

switch.<br />

replace switch.<br />

go to step 20.<br />

S<br />

T<br />

E<br />

P<br />

23a<br />

LW/LB<br />

1000<br />

RESULTS<br />

Check of Ignitor<br />

Test for 40-70 ohms resistance through the ignitor’s detached wires<br />

from the upper terminal strip terminals 5 and 6. Ignitor is cold.<br />

If the meter:<br />

then<br />

does not read between 45 and 75<br />

replace the ignitor.<br />

does read between 45 and 75 ohms go to Step 25a.<br />

A.O. <strong>Smith</strong> <strong>Water</strong> Products Co.<br />

Irving, Texas © 1997<br />

38<br />

Service Workbook<br />

Training Department<br />

A.O. <strong>Smith</strong> <strong>Water</strong> Products Co.<br />

Irving, Texas © 1997<br />

43<br />

Service Workbook<br />

Training Department