TABLE 2-5: SOLVER ERROR MESSAGES<br />

ERROR NUMBER ERROR MESSAGE EXPLANATION<br />

7081 No parameter name given The parametric solver does not find a name<br />

for the parameter. Check the Name of<br />

parameter edit field on the General page of<br />

the Solver Manager.<br />

7092 Out of memory in Algebraic multigrid The Algebraic multigrid solver/<br />

preconditioner ran out of memory. See<br />

error 7144 regarding general<br />

memory-saving tips.<br />

7093 Out of memory during back substitution The solver ran out of memory during back<br />

substitution. See error 7144 regarding<br />

general memory-saving tips.<br />

7094 Out of memory during LU factorization The solver ran out of memory during LU<br />

factorization. See error 7144 regarding<br />

general memory-saving tips.<br />

7111 Singular matrix The system matrix (Jacobian matrix or<br />

stiffness matrix) is singular, so the solver<br />

cannot invert it. Usually this means that the<br />

system is underdetermined. Check that all<br />

equations are fully specified and that the<br />

boundary conditions are appropriate. For<br />

instance, in a stationary model you usually<br />

need to have a Dirichlet condition on some<br />

boundary. A singular matrix could also<br />

occur if mesh elements are of too low<br />

quality. If the minimum element quality is<br />

less than 0.005 you might be in trouble.<br />

Another reason for this error message is<br />

that you have different element orders for<br />

two variables that are coupled by, for<br />

example, a weak constraint. Use the same<br />

element order for all variables that are<br />

coupled.<br />

7136 Very ill-conditioned preconditioner. The<br />

relative residual is more than 1000 times<br />

larger than the relative tolerance<br />

You need to improve the quality of the<br />

preconditioner to get an accurate solution.<br />

For the Incomplete LU preconditioner,<br />

lower the drop tolerance.<br />

ERROR MESSAGES | 417