Medium Voltage Power Cables Catalogue - AEC Online
Medium Voltage Power Cables Catalogue - AEC Online
Medium Voltage Power Cables Catalogue - AEC Online
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
MEDIUM VOLTAGE CABLES<br />
8.7 / 15 kV<br />
TECHNICAL DATA<br />
Rated voltage U o / U (U m ) 8.7 / 15 (17.5) kV<br />
Impulse test voltage (peak value) 95 kV<br />
<strong>Power</strong> frequency test voltage for 5 minutes 30.5 kV<br />
Max. conductor operating temperature at Normal conditions 90 °C<br />
Max. conductor operating temperature at Emergency conditions 130 °C<br />
Max. conductor operating temperature at Short circuit conditions 250 °C<br />
Min. bending radius during installation in terms of cable outer diameter 12 Ø<br />
Constructional Data<br />
Nominal<br />
area of<br />
conductor<br />
Conductor<br />
Approx.<br />
conductor<br />
diameter<br />
Insulation Screen Armour Packing<br />
Thickness of insulation layers<br />
C.S XLPE I.S<br />
Min. Nom. Min.<br />
Approx.<br />
metallic<br />
screen tape<br />
thickness<br />
Wire<br />
diameter<br />
Approx.<br />
overall<br />
diameter<br />
Approx.<br />
overall<br />
weight<br />
Standard<br />
cutting<br />
length<br />
± 5 %<br />
mm 2 mm mm mm mm mm mm mm kg / km m<br />
25 5.85 0.3 4.5 0.3 0.076 2.50 50.7 4081 1000<br />
35 6.90 0.3 4.5 0.3 0.076 2.50 53.0 4391 1000<br />
50 8.10 0.3 4.5 0.3 0.076 2.50 56.0 4827 1000<br />
70 9.70 0.3 4.5 0.3 0.076 2.50 59.7 5404 1000<br />
95 11.30 0.3 4.5 0.3 0.076 2.50 63.7 6075 500<br />
120 12.60 0.3 4.5 0.3 0.076 2.50 66.9 6698 500<br />
150 14.10 0.3 4.5 0.3 0.076 3.15 72.3 8258 500<br />
185 15.80 0.3 4.5 0.3 0.076 3.15 76.3 9081 500<br />
240 18.10 0.3 4.5 0.3 0.076 3.15 81.9 10354 400<br />
300 20.50 0.3 4.5 0.3 0.076 3.15 87.7 11684 400<br />
400 23.10 0.3 4.5 0.3 0.076 3.15 93.9 13275 350<br />
Cable Code<br />
A316XJ3BBWMRDXXI0MR<br />
A317XJ3BBWMRDXXI0MR<br />
A318XJ3BBWMRDXXI0MR<br />
A319XJ3BBWMRDXXI0MR<br />
A345XJ3BBWMRDXXI0MF<br />
A346XJ3BBWMRDXXI0MF<br />
A347XJ3BBWMRDXXI0MF<br />
A348XJ3BBWMRDXXI0MF<br />
A349XJ3BBWMRDXXI0MU<br />
A350XJ3BBWMRDXXI0MU<br />
A351XJ3BBWMRDXXI0MV<br />
Electrical Data<br />
Nominal<br />
area<br />
of<br />
conductor<br />
Electrical Characteristics<br />
Max. Conductor<br />
Resistance<br />
Reactance<br />
(60 Hz)<br />
DC at<br />
20 °C<br />
AC at<br />
90 °C<br />
Impedance<br />
(90 °C,<br />
60 Hz)<br />
Capacitance<br />
Buried direct<br />
in the ground<br />
Continuous Current Ratings<br />
In a buried duct<br />
In air<br />
Fig. (a) Fig. (b) Fig. (c)<br />
mm 2 Ω / km Ω / km Ω / km Ω / km μF / km A A A<br />
25 1.2000 1.5386 0.161 1.547 0.166<br />
96<br />
82<br />
105<br />
35 0.8680 1.1130 0.153 1.123 0.183<br />
114<br />
98<br />
126<br />
50 0.6410 0.8221 0.142 0.834 0.202<br />
133<br />
116<br />
150<br />
70 0.4430 0.5684 0.134 0.584 0.228<br />
162<br />
142<br />
185<br />
95 0.3200 0.4109 0.128 0.430 0.253<br />
193<br />
169<br />
224<br />
120 0.2530 0.3252 0.124 0.348 0.273<br />
217<br />
192<br />
256<br />
150 0.2060 0.2652 0.120 0.291 0.297<br />
243<br />
215<br />
289<br />
185 0.1640 0.2117 0.115 0.241 0.324<br />
273<br />
243<br />
329<br />
240 0.1250 0.1622 0.111 0.197 0.360<br />
312<br />
280<br />
384<br />
300 0.1000 0.1308 0.107 0.169 0.397<br />
348<br />
314<br />
434<br />
400 0.0778 0.1032 0.104 0.146 0.438<br />
390<br />
354<br />
495<br />
Fig. (a)<br />
Fig. (b)<br />
0.3 x De<br />
Fig. (c)