4.8 Junction-Depth and Impurity profile Measurement<br />

- After grooving operation, the junction is delineated using a chemical etchant<br />

which stains the pn junction. Concentrated hydrofluoric acid with 0.1~0.5% nitric<br />

acid can be used as a stain. The distances a and b are measured through a<br />

microscope, and the x j is calculated using Eq(4.20).<br />

Figure 4.20<br />

Junction-depth measurement by the<br />

groove-and-stain technique. The<br />

distance a and b are measured through<br />

a microscope, and the junction depth is<br />

calculated using Eq.(4.20).<br />

32