GARTEUR LIMITED<br />
D.6 Tables<br />
Time hours<br />
Coating As-deposited Passivated<br />
ED <strong>Cadmium</strong> 335 335<br />
ED Zinc-nickel 335 *<br />
ED Zinc-cobalt-iron 1000<br />
PVD Aluminium 1000 *<br />
ED Aluminium NT NT<br />
UMS Aluminium-magnesium NT NT<br />
Delta-tone/Delta-coat * *<br />
SermeTel (984) NT NT<br />
* No rusting detected NT - not tested<br />
Table D1; Kontakt Korrosions Test - Time to rust in screw heads<br />
Aluminium alloy Self corrosion rate, R o ,<br />
(mg.dm -2 .day -1 )<br />
2014-T6 5.9<br />
7075-T6 4.2<br />
Table D2; Self corrosion rates of aluminium alloys<br />
in 600mmol /litre sodium chloride solution<br />
Page 74<br />
GARTEUR SM/AG17 TP128