26.04.2015 Views

Cadmium Substitution - garteur

Cadmium Substitution - garteur

Cadmium Substitution - garteur

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GARTEUR LIMITED<br />

D.6 Tables<br />

Time hours<br />

Coating As-deposited Passivated<br />

ED <strong>Cadmium</strong> 335 335<br />

ED Zinc-nickel 335 *<br />

ED Zinc-cobalt-iron 1000<br />

PVD Aluminium 1000 *<br />

ED Aluminium NT NT<br />

UMS Aluminium-magnesium NT NT<br />

Delta-tone/Delta-coat * *<br />

SermeTel (984) NT NT<br />

* No rusting detected NT - not tested<br />

Table D1; Kontakt Korrosions Test - Time to rust in screw heads<br />

Aluminium alloy Self corrosion rate, R o ,<br />

(mg.dm -2 .day -1 )<br />

2014-T6 5.9<br />

7075-T6 4.2<br />

Table D2; Self corrosion rates of aluminium alloys<br />

in 600mmol /litre sodium chloride solution<br />

Page 74<br />

GARTEUR SM/AG17 TP128