15.05.2015 Views

NI 43-101 Preliminary Economic Assessment - Verde Potash

NI 43-101 Preliminary Economic Assessment - Verde Potash

NI 43-101 Preliminary Economic Assessment - Verde Potash

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Verde</strong> <strong>Potash</strong> Plc 9-3<br />

Cerrado <strong>Verde</strong> Project<br />

<strong>NI</strong> <strong>43</strong>-<strong>101</strong> <strong>Preliminary</strong> <strong>Economic</strong> <strong>Assessment</strong><br />

9.2.1 Quality Controls and Quality Assurance<br />

At the time of the drilling for Funchal Norte Target, <strong>Verde</strong> did not have appropriate internal<br />

QA/QC systems. Future drilling should include at least one twinned hole from the existing set<br />

that has good QA/QC in place that could be used to verify the values from the present reverse<br />

circulation drilling program.<br />

In May 2010, <strong>Verde</strong> introduced a QA/QC program. For the internal control reference, at every<br />

20 routine samples, a certified standard, a powder blank and a duplicate was inserted and sent to<br />

laboratory.<br />

Initially, duplicates were prepared from the splitting of previous sample pulp. After analysis at<br />

SGS laboratory, the pulp were returned and forwarded to analysis at the ALS Brasil Ltda<br />

laboratory, located at Vespasiano, Minas Gerais State. From there, the pulps were sent to ALS<br />

laboratory located in Lima, Peru for analysis. The pulps are analyzed by XRF and LOI. The<br />

ALS quality management system complies with the requirements of the International Standards<br />

ISO 9001:2008 and ISO/IEC 17025:2005. Quality control samples are inserted within each<br />

analytical run. Form XRF methods, the minimum number of QA/QC samples are 2 standards, 1<br />

duplicate and 1 blank, introduced every 39 samples. The blank is inserted at the beginning,<br />

standards are inserted at random intervals, and duplicates are analyzed at end of the batch. Every<br />

batch of samples are analyzed has a dual approval and review process. The individual analytical<br />

runs are monitored and approved by the analyst. The results are compared with the initial values<br />

of SGS in graphics for duplicate controls like Thompson and Howarth, QQ and Correlation plots.<br />

This procedure was adopted until sample CV-RCS-2151.<br />

From March 2011 on, starting at the sample CV-RCS-2171, the duplicate was obtained by<br />

quartering the routine sample, verifying, in that way, the whole laboratory sample preparation<br />

process.<br />

For the accuracy control, the Australian GeoStats Phosphate certified reference material and<br />

Brazilian Instituto de Pesquisas Tecnológicas reference material were used. There were<br />

submitted to SGS for conventional XRF analysis. The standards certificates are attached at the<br />

end of this report.<br />

The blank material was prepared from pulverized quartz obtained from a Brazilian laboratory<br />

Sulfal Química Ltda. At the time, the company did not have appropriate internal contamination<br />

control. Gravel blank composed by quartz will be provided to verify the contamination of the<br />

sample preparation.<br />

For the external control reference, after analysis at the SGS laboratory, pulps were selected from<br />

routine samples, spaced 20 by 20 and sent to analysis at ALS.<br />

9.2.2 Adequacy of Procedures for Targets 4, 6, 7 10 and 11<br />

The Geosol SGS laboratory, which were performed the preparation and the chemical analysis of<br />

the bulk samples, was inspected in July 12. The inspection of the sample preparation room<br />

confirmed that the procedure described above is satisfactory. The preparation rooms and<br />

equipment are kept clean, and upon the completion of each shift, these rooms are cleaned up. All<br />

laboratories and each equipment is provided with ventilation system and exhaust fans. All<br />

instruments are in serviceable condition. The laboratory operates according to international<br />

standards and the risk of error in chemical analysis can be assessed as low.<br />

SRK Consulting (U.S.), Inc. September 16, 2011<br />

Cerrado <strong>Verde</strong>_<strong>NI</strong> <strong>43</strong>-<strong>101</strong> PEA_3<strong>43</strong>500.020_007_KG

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!