Eurotubi Pressfitting System - Technical Guide ... - Damstahl
Eurotubi Pressfitting System - Technical Guide ... - Damstahl
Eurotubi Pressfitting System - Technical Guide ... - Damstahl
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
TABLES<br />
Tab. 1<br />
Pressing tools compatible with <strong>Eurotubi</strong> <strong>Pressfitting</strong> <strong>System</strong><br />
Brand - Usable range - Diameters available<br />
All the machines, adapters, jaws and chains declared by the manufacturer to be suitable for profile “M”<br />
pressing.<br />
For the mini model, the use for stainless steel Ø 35 is still being validated.<br />
WARNING!<br />
1) The systems with diameters 42 => 108 are compatible exclusively with chain terminals with a minimum of<br />
three sectors. Jaw terminals for diameters 42 and 54 are not accepted as valid, under penalty of the<br />
guarantee being voided.<br />
2) “Dated” models are considered valid if they guarantee the same performance as those currently<br />
commercially available.<br />
3) All models must undergo periodic annual revision, under penalty of any guarantee being voided.<br />
Tab. 2<br />
O-ring: characteristics and applications<br />
Material - Reference standard - Min e max temperature - Max pressure – Applications<br />
- Drinking water<br />
- Heating and cooling<br />
- Fire fighting<br />
- Steam<br />
- Compressed air (oil free)<br />
- Inert gas<br />
- Natural gas<br />
- Methane<br />
- Liquid gas<br />
- Solar<br />
- Oil<br />
- Fuel<br />
- Industrial applications<br />
- Compressed air (with oil)<br />
Tab. 3<br />
Stainless steel pipes for pipeline systems. <strong>Technical</strong> characteristics.<br />
Material - External diameter by thickness - Volume of water contained [dm3/m] - Empty weight [kg/m]<br />
Austenitic stainless steel X2 CrNiMo 17-12-2 n.1.4404 (AISI 316L) according to UNI EN 10088-2, UNI EN<br />
10217-7 and UNI EN 10312<br />
Tensile strength Rm : 490-690 N/mm2<br />
Yield resistance Rp0,2: ≥ 190 N/mm2<br />
Longitudinal Lengthening A: ≥ 40%<br />
Bending radius r : ≥ 3,5 d (for annealed pipes only)<br />
Tab. 4<br />
Stainless steel <strong>Eurotubi</strong> <strong>Pressfitting</strong> <strong>System</strong>. Characteristics for different applications.<br />
Application - Heating and cooling – Steam - Compressed air (oil free) and inert gas - Compressed air (with<br />
oil) - Solar (without steam)<br />
Material OR / colour - Max pressure - Min / max temperature<br />
Reccomendations:<br />
Use the anti freeze at a maximum percentage of 50%<br />
Wet the o-ring with water before inserting the tube into the fitting