Overview of Alarms 11/2006<br />

NCK alarms<br />

1002 System error %1<br />

Parameters: %1 = System error number<br />

Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error<br />

number, provide information on the cause and location of the error.<br />

Reaction: Alarm display.<br />

Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)<br />

Program Clear alarm with the Delete key or NC START.<br />

Continuation:<br />

1003 Alarm pointer for this self-clearing alarm %1 is zero<br />

Parameters: %1 = Incorrect alarm number<br />

Definitions: The address (zero pointer) used by the compile cycle manufacturer or by the operating system for selfclearing<br />

alarms is not allowed in the system.<br />

Reaction: Alarm display.<br />

Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)<br />

Check setCCAlarm/setAlarm (...) call.<br />

Program Clear alarm with the Delete key or NC START.<br />

Continuation:<br />

1004 Alarm reaction to NCK alarm incorrectly configured<br />

Parameters: %1 = Incorrect alarm number<br />

Definitions: The alarm reaction configured by the operating system or the compile cycles manufacturer is<br />

incorrect.<br />

Reaction: NC not ready.<br />

Channel not ready.<br />

Interface signals are set.<br />

Alarm display.<br />

Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)<br />

Change alarm reaction<br />

Program Switch control OFF - ON.<br />

Continuation:<br />

1005 Operating system error %1 parameter %2 %3 %4<br />

Parameters: %1 = Operating system error number<br />

%2 = Operating system error parameter 1<br />

%3 = Operating system error parameter 2<br />

%4 = Operating system error parameter 3<br />

Definitions: This alarm indicates that the operating system has detected a serious error.<br />

Reaction: NC not ready.<br />

Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)<br />

Program Switch control OFF - ON.<br />

Continuation:<br />