Overview of Alarms 11/2006<br />

NCK alarms<br />

4019 Axis container %1 advance not allowed with current status of NCU %2<br />

Parameters: %1 = NCU number<br />

%2 = Axis container number<br />

Definitions: This error only occurs with direct advancing of the container. With direct container advancing, only one<br />

channel is allowed to activate the NC language command for advancing the container. In order to<br />

ensure this, the other channels must have the reset status and the axes must be stationary.<br />

With NCU link, the above condition applies to all channels of the NCU group.<br />

Error parameters:<br />

- 1 : NC Ready missing<br />

- 16: At least one other channel is active<br />

- 35: AXCT axis is active following axis/spindle<br />

- 36: AXCT axis is active leading axis<br />

- 39: Axis/spindle disable active<br />

- 40: Overlaid motion active for AXCT axis<br />

- 41: Axis replacement active for AXCT axis<br />

- 42: Interpolator active for one axis container axis<br />

- 46: Rotating spindle with different Ipo cycle of NCUs<br />

- 47: New-Config active<br />

Reaction: Interpreter stop<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: The program must be canceled with Reset and the zero offset deselected before activating the axis<br />

container switch.<br />

Program Clear alarm with the RESET key. Restart part program<br />

Continuation:<br />

4020 Identifier %1 used several times in machine data %2<br />

Parameters: %1 = String: Name of identifier<br />

%2 = String: MD identifier<br />

Definitions: When determining a name in the NCK tables (arrays) for: machine axes, Euler angles,<br />

Richtungsvektoren, direction vectors, interpolation parameters and intermediate point coordinates, an<br />

identifier has been used that is already in the control.<br />

Reaction: NC not ready.<br />

Mode group not ready, also effective for single axes<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Please inform the authorized personnel/service department. Select for the identifier to be entered a<br />

character string that is not yet used in the system (max. 32 characters).<br />

Program Clear alarm with the RESET key in all channels of this mode group. Restart part program.<br />