Overview of Alarms 11/2006<br />

NCK alarms<br />

1019 Floating point arithmetic error at address %3 in channel %1 task %2 FPU<br />

state %4<br />

Parameters: %1 = Channel number<br />

%2 = Task ID<br />

%3 = Code address of operation that triggered the error<br />

%4 = FPU status<br />

Definitions: The floating point unit of the processor has triggered an exception on account of a computational error.<br />

Reaction: NC not ready.<br />

Mode group not ready, also effective for single axes<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Alarm reaction delay is canceled.<br />

Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)<br />

Program Clear alarm with the RESET key in all channels of this mode group. Restart part program.<br />

Continuation:<br />

1030 System error in link module error code %1 error type %2<br />

Parameters: %1 = Hex-Zahl Link-Error<br />

%2 = Hex-Zahl Link-Error-Type<br />

Definitions: This alarm is not a user error. An internal error has occurred in the software of the link module. Two<br />

parameters are output with this error for debugging purposes. They provide information about the<br />

cause and location of the error.<br />

Reaction: NC not ready.<br />

Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)<br />

Program Switch control OFF - ON.<br />

Continuation:<br />

1031 Link module generated an unspecified error %1 NCU %2 %3 %4<br />

Parameters: %1 = Hex-Zahl unspecified status in stateOfLinkModules<br />

%2 = NCU number<br />

%3 = Command from link module to NCK<br />

%4 = Status of own link<br />

Definitions: This alarm is not a user error.<br />

- 1. If NCU== 0 -> A parameter not equal to zero was not found<br />

- 2. If NCU not equal to zero -> An error which the NC was not able to interpret in the connection to<br />

this NCU. The error is output as a number. It is possible that the NCU link module is running a newer<br />

software version than the NC.<br />

The other parameters are used for error localization in the NC/LINK-MODUL software.<br />

Reaction: NC not ready.<br />

Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)<br />

Program Switch control OFF - ON.<br />

Continuation:<br />

2-20<br />

© Siemens AG, 2006. All rights reserved<br />

<strong>SINUMERIK</strong>, <strong>SIMODRIVE</strong> <strong>Diagnostics</strong> <strong>Manual</strong> (DA), 11/2006 Edition

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!