Overview of Alarms 11/2006<br />

NCK alarms<br />

1013 Channel %1 system error %2<br />

Parameters: %1 = Channel number<br />

%2 = System error number<br />

Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error<br />

number, provide information on the cause and location of the error.<br />

Reaction: Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)<br />

Program Clear alarm with the RESET key. Restart part program<br />

Continuation:<br />

1014 Channel %1 system error %2<br />

Parameters: %1 = Channel number<br />

%2 = System error number<br />

Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error<br />

number, provide information on the cause and location of the error.<br />

Reaction: Mode group not ready.<br />

Local alarm reaction.<br />

Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)<br />

Program Clear alarm with the RESET key in all channels of this mode group. Restart part program.<br />

Continuation:<br />

1015 Channel %1 axis %2 system error %3<br />

Parameters: %1 = Channel number<br />

%2 = Axis number<br />

%3 = System error number<br />

Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error<br />

number, provide information on the cause and location of the error. Especially with parameter %3<br />

(system error number) = 840001 = Problem with tool management, the identification for the axis is not<br />

contained in parameter %2, but instead, further information for the diagnostics (= Status of the data<br />

management/magazine no./location no./T no.)<br />

Reaction: Local alarm reaction.<br />

Channel not ready.<br />

Interface signals are set.<br />

Alarm display.<br />

Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)<br />

Program Clear alarm with the RESET key. Restart part program<br />