Overview of Alarms 11/2006<br />

NCK alarms<br />

4183 Channel %1 M auxiliary function number %2 used several times (%3 and<br />

%4)<br />

Parameters: %1 = Channel number<br />

%2 = M auxiliary function number<br />

%3 = MD identifier<br />

%4 = MD identifier<br />

Definitions: In the specified machine data, a number has been used several times for the configuration of an M<br />

function.<br />

Reaction: Mode group not ready.<br />

Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Check the specified machine data and create a unique assignment of M auxiliary function numbers.<br />

Program Switch control OFF - ON.<br />

Continuation:<br />

4184 Channel %1 illegally predefined auxiliary function in %2%3, MD reset<br />

Parameters: %1 = Channel number<br />

%2 = MD identifier<br />

%3 = If required, MD index<br />

Definitions: In the specified machine data, a predefined auxiliary function has been illegally configured.<br />

The value set by the user has been reset to the default value by the system.<br />

Reaction: Mode group not ready.<br />

Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Configure a valid value in the specified machine data.<br />

Program Clear alarm with the RESET key. Restart part program<br />

Continuation:<br />

4185 Channel %1 illegal auxiliary function configured %2 %3 %4<br />

Parameters: %1 = Channel number<br />

%2 = Type of auxiliary function<br />

%3 = Extension<br />

%4 = Auxiliary function value<br />

Definitions: An auxiliary function has been illegally configured.<br />

Predefined auxiliary functions cannot be reconfigured by user-defined auxiliary functions.<br />

Reaction: Mode group not ready.<br />

Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Reconfigure the auxiliary function.<br />

Program Clear alarm with the RESET key. Restart part program<br />

Continuation:<br />

2-50<br />