Overview of Alarms 11/2006<br />

NCK alarms<br />

4007 Axis %1 incorrect assignment of master NCU in machine data %2<br />

Parameters: %1 = Axis<br />

%2 = String: MD identifier<br />

Definitions: Machine axes which can be activated on several NCKs through<br />

$MN_AXCONF_LOGIC_MACHAX_TAB must be assigned to a master NCU in<br />

$MA_AXCONF_ASSIGN_MASTER_NCU. For axes that are activated on only one NCU, the number<br />

of this NCU or 0 must be entered as master NCU. An assignment can only be made with<br />

$MA_AXCONF_ASSIGN_MASTER_NCU if the machine axis is also addressed via a channel<br />

($MC_AXCONF_MACHAX_USED+$MN_AXCONF_LOGIC_MACHAX_TAB).<br />

Reaction: NC not ready.<br />

Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Correct $MA_AXCONF_ASSIGN_MASTER_NCU and/or $MN_AXCONF_LOGIC_MACHAX_TAB.<br />

Program Switch control OFF - ON.<br />

Continuation:<br />

4010 Invalid identifier used in machine data %1[%2]<br />

Parameters: %1 = String: MD identifier<br />

%2 = Index: MD array<br />

Definitions: When determining a name in the NCK tables (arrays) for: machine axes, Euler angles,<br />

Richtungsvektoren, direction vectors, interpolation parameters and intermediate point coordinates,<br />

one of the following syntax rules for the identifier to be entered has been violated:<br />

- The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly with a<br />

numerical extension (840D: 1-99, FM-NC: 1-9)<br />

- The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for system variable).<br />

- The identifier must not be a keyword of the NC language (e.g. POSA).<br />

Reaction: NC not ready.<br />

Mode group not ready, also effective for single axes<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Please inform the authorized personnel/service department. Enter the identifier for user-defined<br />

names with correct syntax in the displayed MD.<br />

- Machine axes: AXCONF_MACHAX_NAME_TAB<br />

- Euler angles: EULER_ANGLE_NAME_TAB<br />

- Normal vectors: NORMAL_VECTOR_NAME_TAB<br />

- Direction vectors: 10640 DIR_VECTOR_NAME_TAB<br />

- Interpolation parameters: 10650 IPO_PARAM_NAME_TAB<br />

- Intermediate point coordinates: 10660 INTERMEDIATE_POINT_NAME_TAB<br />

Program Switch control OFF - ON.<br />

Continuation:<br />

2-30<br />

© Siemens AG, 2006. All rights reserved<br />