Overview of Alarms 11/2006<br />

NCK alarms<br />

4040 Channel %1 axis identifier %2 not consistent with machine data %3<br />

Parameters: %1 = Channel number<br />

%2 = String: Axis identifier<br />

%3 = String: MD identifier<br />

%4 = There are not enough channel axes entered in the MD displayed.<br />

Definitions: The use of the specified axis identifier in the displayed MD is not consistent the channel's axis<br />

configuration stated in the MD 20070 AXCONF_MACHAX_USED and MD 20050<br />

AXCONF_GEOAX_ASSIGN_TAB.<br />

Only with active "OEM transformation" compile cycle: There are not enough channel axes entered in<br />

the MD displayed.<br />

Reaction: NC not ready.<br />

Mode group not ready, also effective for single axes<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Please inform the authorized personnel/service department. Check and correct the identifier used in<br />

the MDs 10000 AXCONF_MACHAX_NAME_TAB, 20080 AXCONF_CHANAX_NAME_TAB and/or<br />

20050 AXCONF_GEOAX_NAME_TAB.<br />

Only with active "OEM transformation" compile cycle: In addition to the specified MD, check and<br />

correct MD 24110 TRAFO_AXES_IN_1[n] of the activated OEM transformation according to the<br />

function description.<br />

Program Switch control OFF - ON.<br />

Continuation:<br />

4045 Channel %1 conflict between machine data %2 and machine data %3<br />

Parameters: %1 = Channel number<br />

%2 = String: MD identifier<br />

%3 = String: MD identifier<br />

Definitions: Using the specified machine data %1 leads to a conflict with machine data %2.<br />

Reaction: NC not ready.<br />

Mode group not ready, also effective for single axes<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Correct the specified machine data.<br />

Program Switch control OFF - ON.<br />