Overview of Alarms 11/2006<br />

NCK alarms<br />

3000 Emergency stop<br />

Definitions: The EMERGENCY STOP request is applied to the NCK/PLC interface (DB 10, DBX 56.1).<br />

Reaction: NC not ready.<br />

Mode group not ready, also effective for single axes<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Alarm reaction delay is canceled.<br />

Remedy: Please inform the authorized personnel/service department. Rectify the cause of EMERGENCY<br />

STOP and acknowledge EMERGENCY STOP via the PLC/NCK interface (DB 10, DBX 56, Bit 2).<br />

Program Clear alarm with the RESET key in all channels of this mode group. Restart part program.<br />

Continuation:<br />

3001 Internal emergency stop<br />

Definitions: This alarm is not displayed.<br />

Reaction: NC not ready.<br />

Local alarm reaction.<br />

Mode group not ready, also effective for single axes<br />

NC Start disable in this channel.<br />

NC Stop on alarm.<br />

Remedy: No remedy required<br />

Program Clear alarm with the RESET key in all channels of this mode group. Restart part program.<br />

Continuation:<br />

4000 Channel %1 machine data %2[%3] has gap in axis assignment<br />

Parameters: %1 = Channel number<br />

%2 = String: MD identifier<br />

Definitions: The assignment of a machine axis to a channel by the machine data 20070<br />

AXCONF_MACHAX_USED must be contiguous. At system power-up (Power On) gaps are detected<br />

and displayed as an alarm.<br />

Reaction: NC not ready.<br />

Mode group not ready, also effective for single axes<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Please inform the authorized personnel/service department. The entries for the indices for the<br />

machine axes used in the channels must be contiguous in table $MC_AXCONF_MACHAX_USED.<br />

Channel axis gaps must be enabled via $MN_ENABLE_CHAN_AX_GAP.<br />

Program Switch control OFF - ON.<br />