Overview of Alarms 11/2006<br />

NCK alarms<br />

4101 Position control cycle for digital drive reduced to %1 ms<br />

Parameters: %1 = String (time in ms)<br />

Definitions: The position control clock divisor in the NCK MD 10060 POSCTRL_SYSCLOCK_TIME_RATIO was<br />

set such that a position control cycle time of more than 16 ms resulted. The boundary value for the<br />

drive actuator 611D is however 16 ms.<br />

Reaction: Alarm display.<br />

Remedy: No remedial measures are required. The alarm display is canceled with Reset.<br />

Program Switch control OFF - ON.<br />

Continuation:<br />

4102 Default values for drive cycle times differ<br />

Definitions: External control modules of the 611D bus and the controls within the CCU3 module have different<br />

default values for the current and speed control cycle times.<br />

Reaction: Interpreter stop<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

Remedy: External control modules of the 611D bus and the controls within the CCU3 module have different<br />

default values for the current and speed control cycle times.<br />

Check the specified values and modify accordingly (see MD_CURRCTRL_CYCLE_TIME and<br />

MD_SPEEDCTRL_CYCLE_TIME).<br />

Program Switch control OFF - ON.<br />

Continuation:<br />

4110 IPO cycle factor changed to %1<br />

Parameters: %1 = String (new IPO cycle time)<br />

Definitions: The IPO cycle divisor was set to a value which was not an integral multiple of the position control cycle<br />

divisor. The divisor (MD 10070 IPO_SYSCLOCK_TIME_RATIO) was increased.<br />

IPO_SYSCLOCK_TIME_RATIO has been modified on systems with PROFIBUS DP because of the<br />

modified DP cycle in SDB-Type-2000 (MD 10050 SYSCLOCK_CYCLE_TIME).<br />

Reaction: Alarm display.<br />

Remedy: Machine data 10070 IPO_SYSCLOCK_TIME_RATIO has been modified.<br />

Program Clear alarm with the RESET key. Restart part program<br />

Continuation:<br />

4111 PLC cycle increased to %1 ms<br />

Parameters: %1 = String (new PLC cycle time)<br />

Definitions: The PLC cycle divisor was set to a value which was not an integral multiple of the IPO cycle divisor.<br />

The divisor (MD 10074 PLC_IPO_TIME_RATIO ) has been increased. MD 10074<br />

PLC_IPO_TIME_RATIO has been modified on systems with PROFIBUS DP because of the modified<br />

DP cycle in SDB-Type-2000 (MD 10050 SYSCLOCK_CYCLE_TIME).<br />

Reaction: Alarm display.<br />

Remedy: Machine data 10074 PLC_IPO_TIME_RATIO has been modified.<br />

Program Clear alarm with the RESET key. Restart part program<br />

Continuation:<br />

4112 Servo cycle changed to %1 ms<br />

Parameters: %1 = String (new servo cycle time)<br />

Definitions: MD 10060 POSCTRL_SYSCLOCK_TIME_RATIO has been modified on systems with PROFIBUS<br />

DP because of the modified DP cycle in SDB-Type-2000 (10050 SYSCLOCK_CYCLE_TIME).<br />

Reaction: Alarm display.<br />

Remedy: Machine data 10060 POSCTRL_SYSCLOCK_TIME_RATIO RATIO has been modified.<br />

Program Clear alarm with the RESET key. Restart part program<br />

Continuation:<br />