Overview of Alarms 11/2006<br />

NCK alarms<br />

4013 Invalid NCU link configuration by machine data %1 = %2 , on NCU_1 = %3<br />

Parameters: %1 = String: MD identifier<br />

%2 = Index: MD array<br />

%3 = MD value of master NCU<br />

Definitions: The link module configuration detected on the local NCU is different from the master NCU of the NCU<br />

cluster. The link module configuration defines the system clock time, the communication baudrate and<br />

the maximum number of message transfer retries.<br />

The following machine data are used for this purpose:<br />

- SYSCLOCK_SAMPL_TIME_RATIO,<br />

- IPO_SYSCLOCK_TIME_RATIO,<br />

- LINK_RETRY_CTR,<br />

- LINK_BAUDRATE_SWITCH,<br />

- SYSCLOCK_CYCLE_TIME<br />

The values of these machine data must be the same on all NCUs.<br />

Reaction: NC not ready.<br />

Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: The machine data required for the link module configuration must be the same on all NCUs in the<br />

cluster.<br />

Program Switch control OFF - ON.<br />

Continuation:<br />

4014 Axis %1 defined several times in %2<br />

Parameters: %1 = String: MD identifier<br />

%2 = String: Check and, if necessary, correct the following machine data with reference to the data<br />

sheet:<br />

Definitions: An axis was assigned several times.<br />

The axis can be a:<br />

- Machine axis<br />

- Link axis<br />

- Axis in a container location<br />

Reaction: NC not ready.<br />

Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Define a correct, unique axis assignment.<br />

Program Switch control OFF - ON.<br />

Continuation:<br />

4016 Axis %1 already used by NCU %2<br />

Parameters: %1 = Machine axis index<br />

%2 = NCU number<br />

Definitions: An attempt was made to apply setpoints to one axis from several NCUs. Only occurs with the NCU<br />

link system<br />

Reaction: NC not ready.<br />

Channel not ready.<br />

NC Start disable in this channel.<br />

Interface signals are set.<br />

Alarm display.<br />

NC Stop on alarm.<br />

Remedy: Define a correct, unique axis assignment.<br />

Program Switch control OFF - ON.<br />

Continuation:<br />