100.00<br />
<strong>hill</strong> top<br />
varying g<br />
exp results<br />
grid e<br />
grid f<br />
grid g<br />
height above ground (m)<br />
10.00<br />
1.00<br />
0.0 0.5 1.0 1.5<br />
fractionnal speed up<br />
Figure 3.13<br />
Figure 3.11 : grids e and f show slight discrepancies with experimental results downwind the<br />
top, but fail in predicting downwind the top flow. Grid g gives good results, with remarkable<br />
accuracy for the maximum speed up and velocities on the lee side.<br />
Figure 3.12 : grids e and f give quite good results all the line long, except for the velocity drop<br />
upwind the <strong>hill</strong>. Grid g captures this drop but yields too low velocities everywhere else along<br />
the line.<br />
Figure 3.13 : grid g provides the best results, but there is no significant difference between the<br />
three tested grids.<br />