100.00<br />

<strong>hill</strong> top<br />

varying g<br />

exp results<br />

grid e<br />

grid f<br />

grid g<br />

height above ground (m)<br />

10.00<br />

1.00<br />

0.0 0.5 1.0 1.5<br />

fractionnal speed up<br />

Figure 3.13<br />

Figure 3.11 : grids e and f show slight discrepancies with experimental results downwind the<br />

top, but fail in predicting downwind the top flow. Grid g gives good results, with remarkable<br />

accuracy for the maximum speed up and velocities on the lee side.<br />

Figure 3.12 : grids e and f give quite good results all the line long, except for the velocity drop<br />

upwind the <strong>hill</strong>. Grid g captures this drop but yields too low velocities everywhere else along<br />

the line.<br />

Figure 3.13 : grid g provides the best results, but there is no significant difference between the<br />

three tested grids.<br />

- 23 -