10.07.2015 Views

Lovis 2000 M_ME - Reference Manual.pdf

Lovis 2000 M_ME - Reference Manual.pdf

Lovis 2000 M_ME - Reference Manual.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

7 Settings and Methods SECTION I : <strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong> <strong>Reference</strong>1. Tap "Menu > Setup > Measuring System Settings > <strong>Lovis</strong> Module >Capillary Detection".2. Tap on the check box to activate or deactivate the function.3. Tap to save the new setting.7.1.3 Capillary Filling ModeIn this submenu you can choose between manual capillary filling outside the <strong>Lovis</strong>capillary block and flow-through capillary filling by syringe (or with an Xsample –refer to p. 110, SECTION II : Flow-Through Systems).The <strong>Lovis</strong> capillary block assumes the position set in this submenu as homeposition. It goes to this position after activating the instrument and after everymeasurement.• By default, <strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong> is set to manual filling. In this position the angleof the <strong>Lovis</strong> capillary block is -45°.• The position for flow-through filling is +20°. The front end of the <strong>Lovis</strong>capillary block is lower than the back end. During filling, potential air bubblescan rise with the liquid flow and can easily leave the capillary again.1. Tap "Menu > Setup > Measuring System Settings > <strong>Lovis</strong> Module >Capillary Filling Mode".2. Select :• or• 3. Tap to save the new setting.7.1.4 Polymer Solvents AdministrationThis item is available for instrument firmware version 2.32 only.In this submenu you can enter all solvent data required for testing polymersolutions. The data are stored for future measurements.For additional information on testing polymers with the <strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong>, consultthe Application Report on Polymer Solutions (Doc. No. C72IA023EN)1. Tap "Menu > Setup > Measuring System Settings > <strong>Lovis</strong> Module >Polymer Solvents Administration".A list of all stored solvents comes up. By default, this list is empty.2. Tap on the respective parameter fields to enter or change a solvent’s name,its batch number and the measuring temperature. (After entering a newname or batch no., 20.00 °C are suggested as default temperature).44 C72IB002EN-E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!