10.07.2015 Views

Lovis 2000 M_ME - Reference Manual.pdf

Lovis 2000 M_ME - Reference Manual.pdf

Lovis 2000 M_ME - Reference Manual.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

7 Settings and Methods SECTION I : <strong>Lovis</strong> <strong>2000</strong> M/<strong>ME</strong> <strong>Reference</strong><strong>Lovis</strong> standardFig. 7 - 1Fig. 7 - 2Example Method <strong>Lovis</strong> standardExample Method <strong>Lovis</strong> detailed• <strong>Lovis</strong> Dynamic Viscosity, <strong>Lovis</strong> KinematicViscosity, <strong>Lovis</strong> Average Runtime, <strong>Lovis</strong>Variation Coefficient, <strong>Lovis</strong> Capillary State,<strong>Lovis</strong> Temperature, <strong>Lovis</strong> Density, <strong>Lovis</strong>Condition• Var. Coeff. set by default: 0.10 %• Default measurement mode: S (Standard)• For use without DMA M / DSA M.• If viscosity results are required, the sampledensity must be entered manually in thesample list.• General purpose method.<strong>Lovis</strong> detailed• <strong>Lovis</strong> Runtime Details (runtimes of everyforward and backward run), <strong>Lovis</strong> Density,<strong>Lovis</strong> Capillary State, <strong>Lovis</strong> Temperature,<strong>Lovis</strong> Set Temperature, <strong>Lovis</strong> Condition,<strong>Lovis</strong> Shear Rate, <strong>Lovis</strong> VariationCoefficient, <strong>Lovis</strong> Forward/BackwardDeviation, <strong>Lovis</strong> Measuring Length, <strong>Lovis</strong>Dynamic Viscosity, <strong>Lovis</strong> KinematicViscosity.• Var. Coeff. set by default: 0.10 %• Default measurement mode: S (Standard)• For use without DMA M / DSA M• To get viscosity results, the sample densitymust be entered manually in the sample list.• Provides detailed measuring data.Fig. 7 - 3Example Method <strong>Lovis</strong> / DMA<strong>Lovis</strong> / DMA – available only in combination withDMA M/DSA M• <strong>Lovis</strong> Runtime Details (runtimes of everyforward and backward run), <strong>Lovis</strong> DynamicViscosity, <strong>Lovis</strong> Kinematic Viscosity, <strong>Lovis</strong>Temperature, <strong>Lovis</strong> Capillary State, <strong>Lovis</strong>Variation Coefficient, <strong>Lovis</strong> Shear Rate,Master Condition, Density, DensityTemperature, U-View• Var. Coeff. set by default: 0.10 %• Default measurement mode: S (Standard)• For use with DMA M/DSA M, the measureddensity is used automatically to calculateviscosity results.• For use with DSA M display sound velocityin one output field (e.g. instead of the shearrate). See the Instrument Firmware <strong>Manual</strong>.• General purpose method.46 C72IB002EN-E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!