3. Programme twilight threshold setting: (Not supported on iss2 and later pcbs)Switch 8 ONAdjust Lens V pot as requiredSwitch 6 ON then OFFSwitch 8 OFFReturn Lens V pot to previous position.Enters Programming modeSets twilight threshold (anti-clockwise = twilight threshold darker)Stores twilight threshold adjustment settingExits Programming mode4. Programme alarm output option:Switch 8 ONSwitch 2 OFF then ONSwitch 8 OFFSwitch 2 OFFEnters Programming modeSelects delayed alarm outputExits Programming modeDefault settingN.B. For a new unit, this step should be omitted if immediate alarm output activation is required. However,for a previously programmed unit, the following steps revert from delayed alarm output to immediate outputoperation:Switch 8 ONSwitch 2 ON then OFFSwitch 8 OFFEnters Programming modeReturns unit to default setting (immediate alarm output)Exits Programming mode5. Activate Patrol Always mode:Switch 8 ONSwitch 3 OFF then ONSwitch 8 OFFSwitch 3 OFFEnters Programming modeActivates Patrol modeExits Programming modeDefault settingN.B. For a new unit this step should be omitted if Patrol Always mode is not to be used. However, for apreviously programmed unit, the following steps revert from Patrol Always = ON to the default setting (PatrolAlways = OFF):Switch 8 ONSwitch 3 ON then OFFSwitch 8 OFFEnters Programming modeReturns unit to default setting (Patrol Always mode = OFF)Exits Programming modeSee SETTINGS FOR NORMAL OPERATION, Page 14, for a fuller explanation of Patrol Always mode.6. Activate lens fine response:Switch 8 ONSwitch 7 OFF then ONSwitch 8 OFFSwitch 7 OFFEnters Programming modeActivates lens fine response mode (anti-hunting mode for lenseswith sluggish response)Exits Programming modeDefault settingN.B. For a new unit this step should be omitted if lens fine response mode is not to be used. However, for apreviously programmed unit, in order to revert to the default setting , the following steps should be carriedout:Switch 8 ONSwitch 7 ON then OFFSwitch 8 OFFEnters Programming modeReturns unit to default settingExits Programming modeOnce all programme settings are complete, the DIP switches can be set for their desired normal operationalmodes. This is done with DIP switch 8 in the OFF (left) position. See SETTINGS FOR NORMALOPERATION, Page 14.Telemetry Receiver Installation HandbookRx400DC2 July 2004 Rev6Page_31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!