1|Generating compressed air<br />

Compressors, stationary<br />

40<br />

UniMaster STV<br />

Type Art. no.<br />

Pressure<br />

(bar)<br />

Compressors for universal use –<br />

The space-saving solution with upright vessel<br />

Common features<br />

• V-belt driven 2-cylinder unit with 2-stage<br />

compression for 10 bar increases the output<br />

and guarantees high efficiency<br />

• Vessel with burned-in interior coating<br />

• 15-year rust guarantee on all vessels<br />

• Standard features include: all fittings, such<br />

as electromagnetic valve or pressure switch<br />

with relief valve for fully automatic operation,<br />

motor protection, safety valve, pressure<br />

gauge, check valve, condensate drain cock<br />

and stop cock<br />

• Standard features include: rubber vibration<br />

elements<br />

• Electrical connection 400 V/50 Hz (threephase<br />

current)<br />

• For compressors with a4kWmotor, observe<br />

the regulations stipulated by the local power<br />

station<br />

Suction<br />

capacity<br />

(l/min)<br />

Eff. delivery<br />

quantity<br />

(l/min) 2)<br />

Drive power<br />

(kW)<br />

Speed<br />

(min-1 )<br />

Tank vol.<br />

(l)<br />

• Itiscompulsory for all compressors and<br />

power units above 5.5 kW to be started via an<br />

automatic star-delta switch. This switch is not<br />

included in the scope of delivery but the startup<br />

relief is<br />

• Intermediate cooler and aftercooler quickly<br />

cool the generated compressed air<br />

• The low speed of rotation reduces vibrations,<br />

preserves the compressor components and<br />

reduces noise levels<br />

• Large ventilator flywheel for optimal cooling<br />

• Safety pan available as an option<br />

• Easily accessible condensate trap under the<br />

vessel. Also suitable for simple connection of<br />

an Ecomat condensate discharger<br />

UNM STV 460-10-200 H112001 10 460 375 3,0 1410 200 135 80 3/4“i 850x830x1450<br />

UNM STV 620-10-270 H112002 10 620 485 4,0 1440 270 154 83 3/4“i 850x830x1760<br />

UNM STV 650-10-270 H112003 10 650 520 4,0 950 270 160 83 3/4“i 850x830x1800<br />

UNM STV 850-10-270 3) H112004 10 850 680 5,5 1240 270 170 83 3/4“i 850x830x1800<br />

UNM STV 960-10-500 3) H112005 10 960 750 5,5 1060 500 275 82 1“i 1070x890x2060<br />

1) Sound pressure level at distance of 1maccording to DIN 45635, T13 2) Measured at 8bar as per ISO 1217 3) Please order star-delta switches separately<br />

Safety trough Type Art. no.<br />

• Retrofit set for catching dirt and oil during<br />

maintenance. Consisting of stable steel<br />

plate with safety pan and rubber dampers<br />

Weight<br />

(kg)<br />

Noise<br />

(dB(A)) 1)<br />

Air outlet<br />

Dimensions<br />

(W xDxH)<br />

SW-STV-Set B135001