1|Generating compressed air<br />

Compressors, stationary<br />

AirMaster compressors with<br />

cold dryer on vessel<br />

58<br />

Type Art. no.<br />

Pressure<br />

(bar)<br />

Compressors for continuous operation –<br />

The traditional solution with horizontal vessel<br />

Common features<br />

• The system electronics prevent the system<br />

from starting in the incorrect direction of rotation.<br />

This prevents damage during operation<br />

or after changing set-up location<br />

• The layout of all components (such as the oil<br />

filter, air filter, oil vessel and external microfilter)<br />

saves time and costs during maintenance<br />

work. The detachable housing cover is<br />

also extremely useful<br />

• All elements subject to regular maintenance<br />

are easy to remove and refit<br />

• The clearly laid-out operating panel with<br />

digital display, emergency stop switch and<br />

function diagram provide acomplete overview<br />

and easy access to all functions relevant<br />

Volume<br />

flow<br />

(l/min) 2)<br />

Voltage<br />

(V)<br />

Drive power<br />

(kW)<br />

Tank vol.<br />

(l)<br />

Weight<br />

(kg)<br />

to system operation<br />

• Effective control, warning and safety systems<br />

• Vessel with burned-in interior coating<br />

• 15-year rust guarantee on all vessels<br />

• Improved compressed air quality. The cold<br />

dryer draws the unwanted condensation<br />

water from the compressed air. Standard<br />

features include abypass line for dryer maintenance.<br />

AMD 4-10 F1-270 DK H415443 10 435 400 4,0 270 217 63 3/4“i 1310x650x1440<br />

AMD 5-10 F1-270 DK H415543 10 610 400 5,5 270 220 69 3/4“i 1310x650x1440<br />

AMD 7-10 F1-270 DK H415643 10 930 400 7,5 270 223 70 3/4“i 1310x650x1440<br />

1) Sound pressure level at distance of 1maccording to DIN 45635, T13 2) Max. volume flowatservice pressure in acc. with ISO 1217 (service pressure =pressure specification -1bar)<br />

AirMaster compressors on<br />

tandem vessel<br />

Type Art. no.<br />

Pressure<br />

(bar)<br />

Compressors for continuous operation –<br />

Tandem vessel, no technical inspection required<br />

Common features<br />

• The system electronics prevent the system<br />

from starting in the incorrect direction of<br />

rotation. This prevents damage during operation<br />

or after changing set-up location<br />

• The layout of all components (such as the oil<br />

filter, air filter, oil vessel and external microfilter)<br />

saves time and costs during maintenance<br />

work. The detachable housing cover is<br />

also extremely useful<br />

• All elements subject to regular maintenance<br />

are easy to remove and refit<br />

• The clearly laid-out operating panel with<br />

digital display, emergency stop switch<br />

and function diagram provide acomplete<br />

overview and easy access to all functions<br />

relevant to system operation<br />

Volume<br />

flow<br />

(l/min) 2)<br />

Voltage<br />

(V)<br />

Drive power<br />

(kW)<br />

Tank vol.<br />

(l)<br />

Weight<br />

(kg)<br />

Noise<br />

(dB(A)) 1)<br />

Air outlet<br />

Dimensions<br />

(W xDxH)<br />

• Effective control, warning and safety systems<br />

• Vessel with burned-in interior coating<br />

• 15-year rust guarantee on all vessels<br />

• Does not require Technical Inspection Authority<br />

certification because of type approval<br />

test in accordance with Industrial Safety<br />

Regulation §17. No set-up inspection or<br />

other repeat inspections. Testing by aqualified<br />

expert is sufficient.<br />

AMD 4-10 F1-180 H415450 10 435 400 4,0 2x90 226 63 3/4“i 1200x800x1480<br />

AMD 5-10 F1-180 H415550 10 610 400 5,5 2x90 229 69 3/4“i 1200x800x1480<br />

AMD 7-10 F1-180 H415650 10 930 400 7,5 2x90 232 70 3/4“i 1200x800x1480<br />

1) Sound pressure level at distance of 1maccording to DIN 45635, T13 2) Max. volume flowatservice pressure in acc. with ISO 1217 (service pressure =pressure specification -1bar)<br />

Noise<br />

(dB(A)) 1)<br />

Air outlet<br />

Dimensions<br />

(W xDxH)