FEPI and PLM FEPI<br />
FEPI Output Status<br />
Error Messages and Fault Isolation<br />
When Start Data (output) instruction execution is initiated, the line module status bytes<br />
are cleared and then status conditions are accumulated to indicate the cause of abnormal<br />
termination. The Read Status command, issued to the line module by the IOP on<br />
termination, causes two bytes of status to be returned to the IOP. The IOP adds the status<br />
bits for which it is responsible. The resulting status format, as stored in the Message<br />
Control Table, is as follows:<br />
���������������������������������������������������������� �������<br />
������ � � ���� � ������� �<br />
������ � � ����� � � ����� �<br />
������������������������������������������������ �����������������<br />
���������������������������������������������������������� �������<br />
� ��� � ������� � �� � ���� � � ���� ������� �<br />
� ����� � ������ ��������� ���� � � ��� ������� �<br />
������������������������������������������������ �����������������<br />
Bit 20 Set if output response timer expires. This action causes unconditional<br />
termination. (If the response timer is loaded with zero, the timer is disabled and<br />
this bit is not set.)<br />
Note: The response timer activates as soon as it is loaded with a non-zero<br />
value during Start Data Transmit execution. The response timer stops<br />
when the output is completed.<br />
Bit 23 Set by the line module if the output is terminated by System Reset from the host.<br />
This action causes unconditional termination.<br />
Bit 24 Set by the line module if the output is terminated by selective reset from the host.<br />
This action causes unconditional termination.<br />
Bit 26 Set by the line module if a data parity error on the SU00486 channel is detected<br />
and reported by the host resident master line module. This action causes<br />
unconditional termination.<br />
Bit 27 Set by the line module if no Read or Pre-read command from the host was active<br />
when the output Start Data Transmit was executed. This action causes<br />
unconditional termination.<br />
Bit 28 Set by the line module when an output data transfer is terminated either by the<br />
IOP or the host and the master or the slave line module is left holding data it is<br />
unable to transfer to the host.<br />
Bit 30 Set by the line module if the output is terminated by a Stop sequence from the<br />
host. This action causes unconditional termination.<br />
7431 8080–202 B–47