Configuring Ports<br />
Auto Enable Ports<br />
This option directs TL3 to automatically enable and test ports. During auto configuration,<br />
the hardware ID of a line module is used to search a table of test chains. The appropriate<br />
microcode for the option selected by TL3 is loaded into the line module and the PP chain<br />
is started. The parameter line options (port, repeat count, throttle, and loopback) have<br />
the same functions as the Enable Ports option. TL3 can not automatically enable all line<br />
modules. A list of the line modules and their hardware IDs that can be automatically<br />
enabled by TL3 follows in Table 2–43. Figure 2–7 illustrates the Automatic Port<br />
Configuration menu.<br />
Table 2–43. Line Modules and Hardware IDs<br />
Hardware ID Line Modules<br />
19 FEPI<br />
40 Low Cost Async<br />
44 Multi-Line Async (4X1)<br />
45 Video Text 4X1<br />
50 Low Cost Sync<br />
54 Sync/Async RS-232 (4X1)<br />
55 Sync/Async RS-232 (4X1) Dual Bus<br />
60 Med SPD RS-449 (MSLLM)<br />
61 Med SPD X.21 Dual Bus<br />
64 DCSS 250K BPS CX<br />
65 Twisted Pair<br />
66 MSLLM V.35<br />
67 Med SPD RS-232 or Dual Bus<br />
6F Med SPD No Cable<br />
70 High SPD Loadable RS-449<br />
71 High SPD Loadable X.21<br />
7D High SPD Bell 303<br />
7E High SPD V.35<br />
7F High SPD No Cable<br />
A0 802.3 Ethernet LAN<br />
A1 4X1 HS T1/E1 (ILM20-HS)<br />
A2 Dual Bus Token Ring (ILM40-TR)<br />
Continued<br />
2–28 7431 8080–202