Error Messages and Fault Isolation<br />

Bit 22 Set by the line module if the line module is off-line to the host when output SDI<br />

execution is attempted. This bit is always set when the line module is off-line,<br />

even during loopback operations. However, in the latter case, the off-line<br />

condition does not terminate the data transfer.<br />

Bit 23 Set by the line module if the output is terminated by a System Reset from the host.<br />

Bit 24 Set by the line module if the output is terminated by a Selective Reset from the<br />

host.<br />

Bit 25 Set by the line module if the output is terminated by an interface disconnect or a<br />

terminate command from the host.<br />

Bit 26 Set by the line module if a data parity error is detected during data transfer from<br />

the host. This action causes a conditional termination.<br />

Bit 27 Set by the line module if no Write command from the host was active when the<br />

input Start Data Transmit was executed. This bit can be set even though the<br />

channel state indicated a Write command was active if the line module received a<br />

Terminate command or ISS with Interface Disconnect before the Start Data<br />

Transmit was executed.<br />

Bit 28 Set by the line module when an input data transfer is terminated either by the CLC<br />

or the host and the line module is holding data it is unable to transfer to the CLC.<br />

Bit 29 Set by the line module if function flag bit 13 (loopback) is set and the line module<br />

is on line, or if function flag bit 13 is not set and the line module is off-line. In the<br />

latter case, the Off-line bit (bit 22) is also set.<br />

Bit 30 Set by the line module if the input is terminated by a Stop sequence from the host.<br />

Bit 31 The CLC sets this bit if a status bit is set and its corresponding chain flag is clear.<br />

This action occurs only after the LM status is passed to the CLC. The line module<br />

does not set this bit.<br />

B–60 7431 8080–202