Error Messages and Fault Isolation<br />

Bit 31 The IOP sets this bit if a status bit is set and its corresponding chain flag is clear.<br />

This action occurs only after the LM status is passed to the IOP. The line module<br />

does not set this bit.<br />

FEPI Input Status<br />

When Start Data (Input) instruction execution is initiated, the line module status bytes are<br />

cleared and then status conditions are accumulated to indicate the cause of abnormal<br />

termination. The Read Status command, issued to the line module by the IOP on<br />

termination, causes two bytes of status to be returned to the IOP.<br />

The IOP adds the status bits for which it is responsible. The resulting status format, as<br />

stored in the Message Control Table, is as follows:<br />

���������������������������������������������������������� �������<br />

����� � �� � ����� � � ���� � ������� �<br />

������ � ������� ����� � � ����� � � ����� �<br />

������������������������������������������������ �����������������<br />

���������������������������������������������������������� �������<br />

� ��� � ������� � �� � ���� � � ���� ������� �<br />

� ����� � ������ ��������� ���� � � ��� ������� �<br />

������������������������������������������������ �����������������<br />

Bit 16 Set by the IOP when allocating input space and the zeroed buffer pool is empty.<br />

This action causes unconditional termination. The line module does not set this<br />

bit.<br />

Bit 17 Set by the IOP when the input limit is reached and input chain flag 17 is set. The<br />

line module does not set this bit. This action causes unconditional termination.<br />

Bit 20 Set if input response timer expires. This action causes unconditional termination.<br />

(If the response timer is loaded with zero, the timer is disabled and this bit is not<br />

set.)<br />

Note: The response timer goes active as soon as it is loaded with a non-zero<br />

value during Start Data Transmit execution. The response timer stops<br />

when the input is completed.<br />

Bit 23 Set by the line module if the input is terminated by a System Reset from the host.<br />

This action causes unconditional termination.<br />

Bit 24 Set by the line module if the input is terminated by selective reset from the host.<br />

This action causes unconditional termination.<br />

Bit 26 Set by the line module if a data parity error is detected during data transfer from<br />

the host. This action causes unconditional termination.<br />

Bit 27 Set by the line module if no Write or Pre-write command from the host was active<br />

when the input Start Data Transmit was executed. This action causes<br />

unconditional termination.<br />

B–48 7431 8080–202