8<br />

8. Appendix A - Sitemap<br />

Main Menu Horizontal menu Page content<br />

[0] Setup<br />

↳<br />

Submenu<br />

[0] Calibration [0] Sensors [0] Irradiation sensor scale: mV<br />

(1000 W/m2 )<br />

[0] Irradiation sensor temp. coeff.:<br />

%/°C<br />

[0] PV temp offset: 2 °C<br />

[0] Ambient temp offset: °C<br />

[0] S0 scale: pulses/kWh<br />

[0] PV Array [0] PV1 Array area: m2 [0] PV1 Array power: W<br />

[0] PV2 Array area: m2 [0] PV2 Array power: W<br />

[0] PV3 Array area: m2 [0] PV3 Array power: W<br />

[0] Environment Here the values for CO2 emission<br />

and revenue calculation are entered.<br />

[0] Communication [0] RS485 Setup [0] Network:<br />

[0] Subnet:<br />

[0] Address:<br />

[0] IP Setup [0] Configuration Automatic/manual<br />

[0] IP address:<br />

[0] Subnet mask:<br />

[0] Default gateway:<br />

[0] DNS Server:<br />

[0] Remote access [2] Change functional safety setting:<br />

[0] External Alarm [0] Alarm: Enable/Disable<br />

[0] Alarm timeout<br />

[0] Stop alarm<br />

[0] Test alarm<br />

[0] <strong>Inverter</strong> details [0] General [0] <strong>Inverter</strong> name:<br />

[0] Group name:<br />

[0] Master mode:<br />

[0] List of follower inverters<br />

[1] Date and time [1] Time:<br />

[1] Date:<br />

[1] Time zone:<br />

[1] Reset max values Reset the max values of the inverter<br />

[0] Logging [0] Logging interval:<br />

[0] Logging capacity:<br />

[1] Delete event log<br />

[1] Delete Production log<br />

[1] Delete Energy log<br />

[1] Delete irradiation log<br />

[0] Messaging [0] Enable/disable messaging for<br />

the individual inverter<br />

[0] Security Change the current security level<br />

of the inverter.<br />

[0] Setup details [0] Setup details [0] Language:<br />

[2] Country3 :<br />

[2] 10 min mean3 [2] 10 min. mean voltage: V<br />

[2] Time to disconnect: ms<br />

[2] ROCOF3 [2] ROCOF limit: Hz/s<br />

[2] Time to disconnect: ms<br />

[1] PV Configuration PV Configuration, individual or parallel<br />

[1] PV 1 configuration<br />

[1] PV 2 configuration<br />

[1] PV 3 configuration1 [1] Force inverter power up Turns on grid supply to the control<br />

board.<br />

Table 8.10: <strong>Inverter</strong> View - Continued<br />