11.07.2015 Views

UM-0046-A0 - DT500 Concise Users Manual - dataTaker

UM-0046-A0 - DT500 Concise Users Manual - dataTaker

UM-0046-A0 - DT500 Concise Users Manual - dataTaker

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Appendix — Firmware Change History Notes ....Versionand DateDescription1.00 12/4/90DT50 & <strong>DT500</strong> released1.10 26/7/90 Major RevisionSyntax changes to schedules & commandsCard operation changed/A, /C, /S, /Y switch changesNew sensor support Ni RTD’s, Thermistors1.11 to 1.20 4/6/91Various minor bug fixesPASSWORD addedImproved 3 wire resistance calibration2.00 2/5/91 Major RevisionCard operation changedBEGIN & END added and append droppedExpression evaluation addedDifference, integrate & rate functions addedMinor syntax changesChanges to /C, /G, /N, /Z switchesChannel ID text addedLCD display support added2.01 to 2.03 24/5/91Various bug fixesDEL character processing change2.10 23/8/91 Significant RevisionTime and date automatically storedUNLOAD from date to date addedHistograms addedCounter operation changedVariables as ALARM setpoints allowedFloating point rounds rather than truncate2.11 and 2.12 20/9/91Minor bug fixes2.90 to 2.99 24/12/91 Significant RevMemory card changes - incompatible/L, /U, /Z switches changedUNLOAD selectable from card or internalSTATUS10-13 addedSeveral ALARM bugs fixed3.00 24/12/91 Consolidation ReleaseOld checksum UNLOAD /P removedNetwork performance improved3.01 to 3.05 15/5/92DT505 support addedVibrating wire sensor support addedInternal channel addressing change (2+%V)ES extra samples channel option addedBaud rate switch function changed slightly/J, /V, /X switches addedSerial port commands addedCEM support addedRepeating ALARMR added3.10 4/6/92Allow program to be placed in EPROMNew switch /A to control ALARMs displayES9 default channel option for FW channelsP7 - network turnaround time for radio linksP22 - maximum number of significant digits6WARN for backlight without flashing added3.11 15/6/921#..5# addressing bug fixedModification to 3 wire calibration3.12 to 3.24 21/10/92Various bug fixes✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶CardNetworkOperationalNew FeaturePage✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶3, 88114, 16138375, 711512138854, 189781181084, 5451311132791811,1241110, 11124Versionand DateDescription3.30 15/2/93Reduced lower frequency limit to 0.1HzModify scaling of bridge channel typesBaud rate selection changeTEST command extendedSystem timers synchronised if time resetGrey code function F7 addedP21 data return address added3.31 25/3/93P33 field width added3.32 to 3.36 1/7/93Various bug fixesBug fix to analog readings following delay4-20mA current loop restriction removedVibrating wire settling delay changed3.40 8/12/93PCMCIA card capability addedCTEST card check command added3.42 26/04/94Some bug fixesXON / XOFF handling modifiedDay of year added, accessed as 15SV3.44 03/06/94Some minor bug fixes3.45 10/03/95Fixed bug where logger can get severalcommands behind4.00 01/09/95Added support for hardware clockAdded support for multiple insertions ofmemory cards for same programChanged some display messages for cardsAdded ^b for quote characters in alarm textChanged default function key settingsVarious bug fixes4.01 and 4.02Minor bug fixes5.00 01/08/96Version ID change for Datataker Series 2loggers. No changes to firmware.✶✶✶✶Card✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶✶NetworkOperational✶✶✶✶✶✶✶✶New FeaturePage41713106711, 1410, 1148811668, 298, 299, 2312ExplanationThe software built into the Datataker is referred to as firmware, andis placed in Read Only Memory or ROM. This ROM is mounted insidethe Datataker, on the lower circuit board, and is socketed for easilyreplacement. Please contact your dealer for more information aboutROM upgrades.Note: When operating Datatakers in a network, it is advisable thatall loggers in the network be running the same firmware version.Page 34

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!