11.07.2015 Views

Hexavalent Chromium ATCM for Decorative and Hard Chrome

Hexavalent Chromium ATCM for Decorative and Hard Chrome

Hexavalent Chromium ATCM for Decorative and Hard Chrome

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Effective Date: October 24, 2007Method of Compliance1. add-on air pollution controlequipment, or chemical fumesuppressants, or mechanical fumesuppressants (i.e. polyballs)2. chemical fume suppressantscontaining a wetting agent 11Requirement≤ 0.01 milligrams per dry st<strong>and</strong>ardcubic meter of air (mg/dscm)(4.4x10 -6 gr/dscf)≤ 45 dynes per centimeter (dynes/cm)(3.1x10 -3 pound-<strong>for</strong>ce per foot [lbF/ft])Effective April 24, 2008, the chemical fume suppressant used by the facility must meetthe criteria specified in section 93102.8 <strong>and</strong> the surface tension shall be maintainedbelow the value specified in Table 93102.8.(b)Limits that Apply to All Existing <strong>Hexavalent</strong> <strong>Hard</strong> <strong>and</strong> <strong>Decorative</strong><strong>Chromium</strong> Electroplating <strong>and</strong> Chromic Acid Anodizing FacilitiesAfter October 24, 2007.(1) During tank(s) operation, each owner or operator of anexisting hexavalent chromium facility shall control hexavalentchromium emissions discharged to the atmosphere bymeeting the requirements identified below.Table 93102.4: <strong>Hexavalent</strong> <strong>Chromium</strong> Emission Limits <strong>for</strong> Existing TanksAnnualSensitive PermittedEmission LimitationEffective DateReceptorDistance 1Ampere-HoursUse Chemical Fume Suppressants as≤ 330 feet ≤ 20,000 specified in section 93102.8 2 April 24, 2008≤ 330 feet> 20,000 <strong>and</strong>≤ 200,000≤ 330 feet > 200,000> 330 feet ≤ 50,000> 50,000 <strong>and</strong>> 330 feet ≤ 500,000> 330 feet > 500,0001230.0015 milligrams/ampere-hour asmeasured after add-on air pollutioncontrol device(s)0.0015 milligrams/ampere-hour asmeasured after add-on air pollutionOctober 24, 2010October 24, 2009control device(s) 3Use Chemical Fume Suppressant asspecified in section 93102.8 2 April 24, 20080.0015 milligrams/ampere-hour October 24, 20110.0015 milligrams/ampere-hour asmeasured after add-on air pollution October 24, 2009control device(s) 3Distance shall be measured as specified in section 93102.4(b)(2)(A).Alternatively, a facility may install an add-on air pollution control device(s) that controlsemissions to below 0.0015 milligrams per ampere-hour.When annual emissions exceed 15 grams a site specific risk analysis must be conductedby the owner or operator in accordance with the permitting agency’s procedures, unless asite specific risk analysis has already been conducted <strong>and</strong> approved by the permittingagency. The analysis shall be submitted to the permitting agency.15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!