11.07.2015 Views

Hexavalent Chromium ATCM for Decorative and Hard Chrome

Hexavalent Chromium ATCM for Decorative and Hard Chrome

Hexavalent Chromium ATCM for Decorative and Hard Chrome

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Effective Date: October 24, 2007Appendix 2 - Content of Initial Compliance Status ReportsInitial compliance status reports required by subsection 93102.13(b) shall containthe following in<strong>for</strong>mation:1. Company In<strong>for</strong>mation: Facility name, address, owner/operator name,telephone number, <strong>and</strong> the measured distance to the property boundary ofthe nearest sensitive receptor. For facilities that do not have an add-on airpollution control device the measurement shall be the distance, rounded tothe nearest foot, from the edge of the plating or anodizing tank nearest thesensitive receptor to the property line of the nearest sensitive receptor thatexists on October 24, 2007. For facilities with an add-on air pollution controldevice the measurement shall be the distance, rounded to the nearest foot,from the centroid of the stack to the property line of the nearest sensitivereceptor that exists on October 24, 2007;2. The applicable requirements from section 93102.4 <strong>and</strong> the methods thatwere used to determine compliance. A description of the air pollutioncontrol technique <strong>for</strong> each emission point;3. If a facility is using add-on controls to comply provide the following:a) Description of add-on controls <strong>and</strong> a per<strong>for</strong>mance test reportdocumenting the results of the per<strong>for</strong>mance test, which contains theelements listed in Appendix 1;b) If the facility is a hexavalent chromium facility, the actual hexavalentchromium emissions of the facility in pounds per year calculated bymultiplying the emission rate with the actual ampere-hours <strong>for</strong> thepreceding calendar year.c) For monitored parameters 93102.9(b) <strong>and</strong> (c), the specific operatingparameter value, or range of values, that corresponds to compliancewith the applicable emission limit; <strong>and</strong>d) A statement that the owner or operator has completed <strong>and</strong> has on filethe operation <strong>and</strong> maintenance plan as required by section 93102.11.4. If a facility is using in-tank controls to comply, provide the following:a) Description of in-tank controls including name of in tank controls, nameof chemical fume suppressant, surface tension of the electroplating oranodizing bath; <strong>and</strong>46

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!