11.07.2015 Views

Hexavalent Chromium ATCM for Decorative and Hard Chrome

Hexavalent Chromium ATCM for Decorative and Hard Chrome

Hexavalent Chromium ATCM for Decorative and Hard Chrome

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Effective Date: October 24, 2007(d)(e)Pre-Test protocol. Facilities subject to the provisions of section93102.7(a) must submit a pre-test protocol to the permitting agencyat least 60 days prior to conducting a per<strong>for</strong>mance test. The pretestprotocol shall include the per<strong>for</strong>mance test criteria of the enduser <strong>and</strong> all assumptions, required data, <strong>and</strong> calculated targets <strong>for</strong>testing the source target chromium concentration, the preliminarychromium analytical data, <strong>and</strong> the planned sampling parameters.In addition, the pre-test protocol shall include in<strong>for</strong>mation onequipment, logistics, personnel, <strong>and</strong> other resources necessary <strong>for</strong>an efficient <strong>and</strong> coordinated test.Test all emission points. Each emission point subject to therequirements of this regulation must be tested unless a waiver isgranted by U.S. EPA <strong>and</strong> approved by the permitting agency.NOTE: Authority cited: Sections 39600, 39601, 39650, 39658, 39659, 39666, <strong>and</strong> 41511,Health <strong>and</strong> Safety Code. Reference: Sections 39650, 39658, 39659, 39665, 39666, <strong>and</strong> 41511,Health <strong>and</strong> Safety Code; <strong>and</strong> 40 CFR Part 63 Subpart N.§ 93102.8 Chemical Fume Suppressants.Chemical fume suppressants used to comply with sections93102.4 <strong>and</strong> 93102.6(b)(1)(B) shall meet the criteria specified inthis section 93102.8.(a)One or more of the chemical fume suppressants listed inTable 93102.8 shall be used to reduce the surface tension of theelectroplating or anodizing bath(s) below the surface tension valuelisted in Table 93102.8. The surface tension value may bemeasured using either a stalagmometer or a tensiometer.Table 93102.8: Chemical Fume Suppressants Approved <strong>for</strong> Use atSpecified Surface TensionsChemical FumeSuppressant <strong>and</strong>ManufacturerStalagmometerMeasuredSurface Tension(dynes/centimeter)TensiometerMeasured SurfaceTension(dynes/centimeter)Benchbrite CR 1800 ®Benchmark Products < 40 < 35Clepo <strong>Chrome</strong> ®MacDermid < 40 < 35Fumetrol 140 ®Atotech U.S.A. < 40 < 35HCA-6.2 ®Hunter Chemical LLC < 32 < 28HCA-4 ®Hunter Chemical LLC < 32 < 2826

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!