ABB i-bus ® KNXCommissioning3.2.14.1 Parameter windowA: Multiple operationIn this parameter window, all settings are undertaken for parameter windowA: Switching sequences.The explanations also apply for the Inputs B…X.This parameter window is visible if in parameter window Enable Inputs A…X,page 50, the option Switching sequences has been selected in parameterInput A.Enable communication object"Disable" 1 bitOptions: noyes• yes: The 1 bit Block communication object is enabled.This can be used to block the input.NoteIf the input is disabled and the option yes is selected with parameterCyclic sending, the last state is still sent regardless of the block.Using the communication object Block (No. 10), the physical input can bedisabled, but internal sending continues, i.e. the input terminals arephysically disconnected from the application program.The communication object Block (No.10) has no influence on manualoperation.© 2011 ABB STOTZ-KONTAKT GmbH 116