11.07.2015 Views

1.0 - SATA-IO

1.0 - SATA-IO

1.0 - SATA-IO

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2) An IDENTIFY DEVICE command is issued.3) Two READ FPDMA QUEUED commands with same tag (equal to 00h) areissued.4) READ LOG EXT command is issued after device reports erroro NCQ04-03.stc1) COMRESET signal is issued.2) An IDENTIFY DEVICE command is issued.3) If the maximum queue depth of the device is reported to be the maximumvalue of 32, then the test project exits without failure.4) A READ FPDMA QUEUED command with an invalid tag (a tag value morethan the reported maximum queue depth) is issued5) READ LOG EXT command is issued after device reports error• Post processes:• Identify.sts:o Existing and complete execution of IDENTIFY DEVICE Commands in the trace arechecked to verify the proper execution of test project. “ERROR” result is reported ifthe above commands is missed and/or not executed completely.o Bit 8 of WORD 76 of Identify Page data is checked and “N/A” result is reported ifdevice does not support NCQ feature.• NCQ04-01.sts:o Existing of READ FPDMA QUEUED and READ LOG EXT commands in the traceare checked to verify the proper execution of test project. “ERROR” result isreported if one of the above commands is missed and/or not executed completely.o The device response to malformed command (out of range LBA) is checked thatshould be one of these cases:1) A RD2H with ERR bit set, DRDY bit set and DF bit cleared in Statusregister, ABRT bit or IDNF set in Error register and Interrupt bit (I) set2) A RD2H with ERR bit cleared followed by a Set Device Bit FIS containingERR bit set, BSY bit cleared, DF bit cleared and DRDY bit set in Statusregister, ABRT or IDNF bit set in Error field and Interrupt bit (I) seto The existence of Set Device Bit FIS after issuance of READ LOG EXT command ischecked. Also its content is verified to be: ERR bit in Status register cleared Interrupt bit (I) cleared SActive Register equals to ‘FFFFFFFFh’o NQ Bit in returned log page (payload of READ LOG EXT) is verified to be clearedand the Tag of erring command is verified to be 00h.o If any of the above criteria is not fulfilled, “FAILED” result is reported.• NCQ04-02.sts:o Existing and complete execution of READ DMA and READ LOG EXT commandsin the trace are checked to verify the proper execution of test project. “ERROR”result is reported if one of the above commands is missed and/or not executedcompletely.o The device response to malformed command (duplicated tag) is checked that shouldbe a RD2H with:39 Digital MOI for LeCroy STX Bus Analyzer

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!