Rosemount Tank Radar REX<strong>Reference</strong> <strong>Manual</strong>308018EN, Edition 3BSeptember 20071.2.1 PortsFigure 1-2. Electrical CircuitBoard Layout.P1RP 3500PowerLK 8P2LK 7 LK 1JTAGIC 22IC 21IC 24IC 23LK 3LK 4IC 12 IC 11LK 6IC 10 IC 9 IC 8 IC 7 IC 6 IC 5IC 3 IC 2LK 10LK 2LK 5IC 4ResetEthernet SER 2 SER 3 SER 4 SER 5 SER 6 SER 7 SER 8 SER 9 SER 10 SER 11 SER 12Table 1-2. Communication portsPort Connection Electrical Interface Baud Rate & Communication SettingsEthernet RJ 45 Ethernet Application dependentSER 2 RJ 12 RS 232 as default (1) Must be the same as for SER 6.SER 3 RJ 12 RS 232 as default (1) Application dependentSER 4, Engineering port RJ 12 RS 232 as default (1) Application dependentSER 5 RJ 12 RS 232 only Application dependentSER 6 RJ 12 RS 232 only Must be the same as for SER 2.SER 7 RJ 12 RS 232 as default (1) Must be the same as for SER 11.SER 8 RJ 12 RS 232 as default (1) Must be the same as for SER 12.SER 9 RJ 12 RS 232 as default (1) Application dependentSER 10 RJ 12 RS 232 as default (1) Application dependentSER 11 RJ 12 RS 232 only Must be the same as for SER 7.SER 12 RJ 12 RS 232 only Must be the same as for SER 8.(1) Can also be configured as RS 422, RS 485 or other electrical interface using the correspondingelectrical interface driver module.The <strong>FCU</strong> <strong>2165</strong> has 10 serial connections (SER 2-3, 5-12) of which 4 arereserved for RS 232, see Table 1-2.SER 4 is dedicated as the engineering port. It is normally set to 9600 baud, noparity, 8 data bits and 1 stop bit. It is used by the operating system of the <strong>FCU</strong><strong>2165</strong> to send bootstrap messages at power on or after reset and it alsoprovides local logon capability using a PC with a terminal emulation softwarepackage such as Hyper Terminal in MS Windows. See “Changing IP Address/ <strong>FCU</strong> Name” on page 2-40.The Ethernet port is used for configuration of the <strong>FCU</strong> via a PC withConfiguration Tools software (see pages 2-2 and 2-10)1-4 Section 1. Description of <strong>FCU</strong> <strong>2165</strong>/<strong>2175</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!