12.07.2015 Views

FCU 2165/2175 Reference Manual - Emerson Process Management

FCU 2165/2175 Reference Manual - Emerson Process Management

FCU 2165/2175 Reference Manual - Emerson Process Management

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Reference</strong> <strong>Manual</strong>308018EN, Edition 3BSeptember 2007Rosemount Tank Radar REXSection 1 Description of <strong>FCU</strong> <strong>2165</strong>/<strong>2175</strong>1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-11.2 <strong>FCU</strong> <strong>2165</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-31.3 <strong>FCU</strong> <strong>2175</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-51.4 Field Terminations . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-101.5 Power Connection . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-101.6 Engineering Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-111.7 Ethernet Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-111.8 Reset Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 1-111.9 Green LED – RUNNING . . . . . . . . . . . . . . . . . . . . . . page 1-111.10 Red LED – CPU Activity . . . . . . . . . . . . . . . . . . . . . . page 1-111.1 INTRODUCTION The Rosemount Field Communication Unit, <strong>FCU</strong> <strong>2165</strong>/<strong>2175</strong>, providesseamless integration of tank gauges from different vendors. The <strong>FCU</strong>continuously polls data from field devices such as radar and servo tankgauges, data acquisition units, I/O Modules, other <strong>FCU</strong>s, Enraf ® CIU:s etcand stores data in a buffer memory.With the <strong>FCU</strong> it is possible to connect to devices from vendors such as Enraf ®and Whessoe ® (Varec ® , GPE ® , L&J ® etc. are coming possibilities).Whenever a request for data is received from a host, the <strong>FCU</strong> canimmediately send data from the updated buffer memory. The <strong>FCU</strong> can servicerequests from a wide range of hosts/DCS systems such as RosemountTankMaster ® , Enraf ® Entis, Yokogawa ® , ABB ® , Honeywell ® , Foxboro ® amongothers (it is possible to connect any system using Modbus protocol).The operation of the <strong>FCU</strong> is determined by the configuration downloaded to itby a host configuration program. Configuration information is downloaded tothe <strong>FCU</strong> over the Ethernet network, which can therefore be done remotely.The configuration of the <strong>FCU</strong> can be modified on-line by downloadingmodifications from the host configuration software. For example, new gaugescan be added, a gauge can be modified from one type to another, or movedfrom one port to another.Each of the ports can be configured either as a master or a slave connection,providing ultimate configuration flexibility.The <strong>FCU</strong> <strong>2165</strong> has 10 ports of which 4 are reserved for RS 232. The <strong>FCU</strong><strong>2175</strong> can be ordered with 8, 16, 24 or 32 flexible ports. See pages 1-4 to 1-5.For applications requiring more capacity or when devices are distributed overa large area, multiple <strong>FCU</strong>s can be used. Two <strong>FCU</strong>s can also be connected inparallel with one unit operational and the other as a redundant backup. Thebackup unit is automatically activated in case of a primary unit failure (hotstandby). See “Configuration for Redundancy” on page 2-44.www.rosemount-tg.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!