12.07.2015 Views

Emotron FDU 2.0 AC drive

Emotron FDU 2.0 AC drive

Emotron FDU 2.0 AC drive

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Connect motor cables1. Remove the cable interface plate from the <strong>AC</strong> <strong>drive</strong>housing.2. Put the cables through the glands.3. Strip the cable according to Table 8.4. Connect the stripped cables to the respective motor terminal.5. Put the cable interface plate in place and secure with thefixing screws.6. Tighten the EMC gland with good electrical contact tothe motor and brake chopper cable screens.Placing of motor cablesKeep the motor cables as far away from other cables as possible,especially from control signals. The minimum distancebetween motor cables and control cables is 300 mm.Avoid placing the motor cables in parallel with other cables.The power cables should cross other cables at an angle of90.Long motor cablesIf the connection to the motor is longer than 100 m (forpowers below 7.5 kW please contact <strong>Emotron</strong>), it is possiblethat capacitive current peaks will cause tripping at overcurrent.Using output coils can prevent this. Contact the supplierfor appropriate coils.Switching in motor cablesSwitching in the motor connections is not advisable. In theevent that it cannot be avoided (e.g. emergency or maintenanceswitches) only switch if the current is zero. If this isnot done, the <strong>AC</strong> <strong>drive</strong> can trip as a result of current peaks.3.3 Connection of motor andmains cables for model090 and up<strong>AC</strong> <strong>drive</strong> <strong>FDU</strong>48-090 and up, <strong>FDU</strong>69-090 andupTo simplify the connection of thick motor and mains cablesto the <strong>AC</strong> <strong>drive</strong>, the cable interface plate can be removed.Clamps for screeningCable interfaceMotor cableDC+, DC-, R (optional)Mains cableFig. 25 Connecting motor and mains cables1. Remove the cable interface plate from the <strong>AC</strong> <strong>drive</strong>housing.2. Put the cables through the glands.3. Strip the cable according to Table 8.4. Connect the stripped cables to the respective mains/motor terminal.5. Fix the clamps on appropriate place and tighten thecable in the clamp with good electrical contact to thecable screen.6. Put the cable interface plate in place and secure with thefixing screws.18 Installation <strong>Emotron</strong> AB 01-4428-01r3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!